Beyond the Guidelines: Successful CRT-D Rescue in Patients Unable to Tolerate Guideline-Directed Medical Therapy.
Sashwath Srikanth, Ali Yousif
Department of Cardiology, Baylor Scott and White The Heart Hospital, Plano. · Division of Electrophysiology, Department of Cardiology, Baylor Scott and White The Heart Hospital, Plano. Electronic address: Ali.Yousif@BSWHealth.org.
Key points
From the paper's conclusion- We present two patients with advanced non-ischemic cardiomyopathy, LBBB with markedly prolonged QRS duration (166-168 ms), and LVEF <20%, both of whom were inotrope-dependent and unable to tolerate GDMT.
Abstract
BACKGROUND: Current ACC/AHA/HFSA guidelines endorse cardiac resynchronization therapy with defibrillation (CRT-D) as a Class I recommendation for patients with heart failure with reduced ejection fraction (HFrEF), left bundle branch block (LBBB), and QRS ≥150 ms but only after at least three months of maximally tolerated guideline-directed medical therapy (GDMT). A critical and under-addressed clinical scenario exists - patients with electromechanical dyssynchrony who cannot achieve GDMT optimization due to hypotension, renal dysfunction, or inotrope dependence. Current guidelines do not provide a recommendation pathway for this population, leaving clinicians without evidence-based guidance in a high-stakes decision context. CASE PRESENTATIONS: We present two patients with advanced non-ischemic cardiomyopathy, LBBB with markedly prolonged QRS duration (166-168 ms), and LVEF <20%, both of whom were inotrope-dependent and unable to tolerate GDMT. Neither met traditional prerequisites for CRT-D implantation. Following multidisciplinary evaluation, both patients underwent successful CRT-D implantation, were weaned from intravenous inotropic support, improved from NYHA Class IV to Class II at one year, and had no heart failure hospitalizations during follow-up, with meaningful gains in LVEF in both cases. CLINICAL IMPLICATIONS: CRT-D may serve as a salvage or enabling therapy in select patients with advanced HFrEF and electrical dyssynchrony who are unable to complete the recommended GDMT optimization period. Prospective studies are needed to refine selection criteria in this high-risk population.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Optimisation of guideline-directed medical therapy following cardiac resynchronization therapy in patients with heart failureEuropean Heart Journal · 2026
- Tricuspid regurgitation is a barrier to guideline-directed medical therapy implementation in patients with acute decompensated heart failure and reduced ejection fraction.European heart journal. Valvular and structural heart disease · 2026
- Refining cardiac resynchronization therapy selection in borderline QRS duration patients.Heart rhythm O2 · 2026
- The efficacy of add on cardiac resynchronization therapy (CRT) to symptomatic patients with heart failure with reduced ejection fraction on sacubitril/valsartan treatment as regards left ventricle reverse remodeling and functional improvement.The Egyptian heart journal : (EHJ) : official bulletin of the Egyptian Society of Cardiology · 2026
- Adherence to Guidelines in Patients With Heart Failure and Reduced Ejection Fraction Before Defibrillator Implantation.CJC open · 2026
- Interplay between guideline-directed medical therapy and QRS duration in patients with heart failure and reduced ejection fraction: data from the Swedish Heart Failure registryEuropean Heart Journal · 2026