Emergency Transcatheter Aortic Valve Implantation in Mixed Bicuspid Aortic Valve Disease With a Horizontal Aorta: Return of Spontaneous Circulation Only After Left Ventricular Unloading.
Tommaso Simone, Greta Cattaneo, Luca Testa, Francesco Bedogni, Gaspare Cannone
Department of Clinical and Interventional Cardiology, IRCCS Policlinico San Donato, San Donato Milanese, Milan, Italy. · Department of Clinical and Interventional Cardiology, IRCCS Policlinico San Donato, San Donato Milanese, Milan, Italy. Electronic address: gaspare.cannone@gmail.com.
Key points
From the paper's conclusion- A 74-year-old man with mixed bicuspid aortic valve disease, combining severe calcific stenosis with severe regurgitation, and a left ventricular ejection fraction of 26% presented in normotensive cardiogenic shock with anuria and an arterial lactate of 12 mmol/L.
Abstract
A 74-year-old man with mixed bicuspid aortic valve disease, combining severe calcific stenosis with severe regurgitation, and a left ventricular ejection fraction of 26% presented in normotensive cardiogenic shock with anuria and an arterial lactate of 12 mmol/L. Computed tomography showed a fibrocalcific left-right raphe and an aortic angulation of 66 degrees. Emergency transfemoral transcatheter aortic valve implantation was undertaken. The delivery system could not be advanced across the aortic arch despite escalation of guidewire support, and ventricular fibrillation degenerated into pulseless electrical activity refractory to resuscitation. Peripheral venoarterial extracorporeal membrane oxygenation was established, after which a 29 mm self-expanding prosthesis was implanted with an acceptable haemodynamic result and patent coronary ostia. Pulseless electrical activity nonetheless persisted. Return of spontaneous circulation followed only after a microaxial pump was advanced retrogradely across the freshly deployed prosthesis under fluoroscopic guidance alone, establishing an ECMELLA configuration. The patient died of multiorgan failure two days later. This sequence identifies continued left ventricular loading, rather than any residual valve lesion, as the reason resuscitation failed, and argues for anticipating unloading when extracorporeal support is instituted across a valve just rendered competent in a severely dysfunctional ventricle. The outcome appeared determined by end-organ injury already established before intervention.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Electrical Storm Triggered by Conus Branch Occlusion During Elective Percutaneous Coronary Intervention in Very Severe Aortic Stenosis: Rescue With Balloon Aortic Valvuloplasty Under Venoarterial Extracorporeal Membrane Oxygenation.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2026
- Subclavian VA-ECMO-Supported TAVR and Rotational Atherectomy in Cardiogenic Shock.JACC. Case reports · 2026
- Staged Management with Transcatheter Aortic Valve Replacement in a Patient with ST-Segment Elevation Myocardial Infarction, Low-Gradient Aortic Stenosis, and Recurrent Cardiogenic Shock: A Case Report.Journal of clinical medicine · 2026
- Successful destination therapy after stepwise mechanical circulatory support in a patient with cardiogenic shock following mechanical aortic valve replacementJournal of Artificial Organs · 2026
- Emergency Transcatheter Aortic Valve Implantation for Decompensated Aortic Stenosis accompanied by Cardiogenic Shock.Annals of cardiac anaesthesia · 2026
- Neurologically Intact Recovery After Extracorporeal Cardiopulmonary Resuscitation for Cardiac Arrest Due to Blow-Out-Type Left Ventricular Free Wall Rupture: A Case Report.Cureus · 2026