The Use of Artificial Intelligence and Its Reliability in Grading Drug Information Responses.
Sean P Kane, Riya Kini, Angel John, Jessica Cottreau, Frank Hughes, Rachel Neu, Danielle M Candelario
Department of Pharmacy Practice, College of Pharmacy, Rosalind Franklin University of Medicine and Science, 3333 Green Bay Rd, North Chicago, IL 60064. Electronic address: sean.kane@rosalindfranklin.edu. · Rosalind Franklin University of Medicine and Science, North Chicago, Illinois. Electronic address: riya.kini@my.rfums.org.
Key points
From the paper's conclusion- Despite faculty consensus building and rubric calibration, AI models demonstrated superior grading reliability. Overall, both AI models graded slightly harsher (median 1.2 to 1.7 points lower), which represents about a 5% difference in the overall rubric. AI grading biases were uniformly distributed regardless of essay quality.
Abstract
OBJECTIVE: To compare the reliability of two artificial intelligence (AI) models and pharmacy faculty in grading drug information (DI) responses. METHODS: We retrospectively collected 55 deidentified DI responses written by second-year pharmacy students. A 32-point grading rubric was developed and five faculty graders completed two calibration sessions to ensure grading consistency. Each DI response was graded by three randomly assigned faculty and two AI models (OpenAI ChatGPT 5.2 and Google Gemini 2.5 Flash). Grading reliability was measured using intraclass correlation (ICC[1,1]). Using the mean faculty score as a consensus benchmark, mean absolute error (MAE) evaluated grading differences between AI models and faculty. Proportional bias was assessed using Spearman's correlation. RESULTS: Median total rubric scores were 25.9 points (faculty), 24.2 points (ChatGPT), and 24.7 points (Gemini). Median scores were not different between the two AI models. Reliability was significantly higher for ChatGPT (ICC=.90) and Gemini (ICC=.72) compared to faculty evaluators (ICC=.39). Compared to faculty evaluators, both ChatGPT and Gemini demonstrated an MAE of 2.1 points. Neither model exhibited proportional bias. CONCLUSION: Despite faculty consensus building and rubric calibration, AI models demonstrated superior grading reliability. Overall, both AI models graded slightly harsher (median 1.2 to 1.7 points lower), which represents about a 5% difference in the overall rubric. AI grading biases were uniformly distributed regardless of essay quality.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Comparative Study of Artificial Intelligence and Faculty Rubric‐Based Grading of Pharmacy Student Writing Assignments in an Evidence‐Based Medicine CourseJACCP JOURNAL OF THE AMERICAN COLLEGE OF CLINICAL PHARMACY · 2026
- Can Generative Artificial Intelligence Reliably Score Open-Ended Question Assessments in Undergraduate Medical Education?Medical Science Educator · 2026
- Accuracy and Quality Assessment of Artificial Intelligence Platforms and a Hybrid Evidence-Assisted Model in Responding to Drug Information Questions.American journal of health-system pharmacy : AJHP : official journal of the American Society of Health-System Pharmacists · 2026
- From concepts to clinicals: A comparative study of artificial intelligence platforms for competency-based medical education and postgraduate pharmacology problem-solvingNational Journal of Pharmacology and Therapeutics · 2026
- Comparison of artificial intelligence and lecturers' grading in the evaluation of handwritten open-ended anatomy examinations.Surgical and radiologic anatomy : SRA · 2026
- Evaluation of Clinically‐Focused Artificial Intelligence Chatbots for Answering Drug Information QuestionsJACCP JOURNAL OF THE AMERICAN COLLEGE OF CLINICAL PHARMACY · 2026