Mechanical properties of bidimensional T-loop closing springs compared with conventional T-loops: A 3-dimensional finite element analysis.
Necati Turkmen, Gulnaz Marsan
Department of Orthodontics, Faculty of Dentistry, Istanbul Aydin University, Istanbul, Turkey. Electronic address: necatiturkmen@aydin.edu.tr. · Department of Orthodontics, Faculty of Dentistry, Istanbul University, Istanbul, Turkey.
Key points
From the paper's conclusion- Based on theoretical finite element predictions, the bidimensional T-loop design produces greater forces, moments, and alpha-end moment-to-force ratios than conventional T-loops. Reduced alpha-end bracket-slot play may reduce moment attenuation, offering potential biomechanical advantages for maximum-anchorage retraction. These are theoretical mechanical predictions that require clinical and experimental validation before definitive conclusions can be drawn.
Abstract
INTRODUCTION: T-loop closing springs are widely used for extraction space closure in friction-free orthodontic mechanics. The bidimensional technique exploits differential wire-slot engagement to enhance anterior torque control; however, its application to T-loop design has not been investigated. This study aimed to compare the 3-dimensional force systems produced by conventional and bidimensional T-loop closing springs across different interbracket distances and activation levels using finite element analysis. METHODS: Six 3-dimensional T-loop models were constructed using SolidWorks 2021 (Dassault Systèmes, Vélizy-Villacoublay, France): 3 conventional and 3 bidimensional designs made from 0.016 × 0.022-in stainless steel wire, each modeled at interbracket distances of 6, 8, and 10 mm. All models assumed a 0.022-in bracket slot. The bidimensional variant incorporated a 90° torsion bend at the loop's midportion. Static structural analysis was performed in ANSYS 2021 R2 (ANSYS Inc, Canonsburg, Pa) with cinch-back activations of 2 mm and 4 mm. Digital sensor probes recorded forces and moments at both wire ends along 3 spatial axes. RESULTS: Bidimensional T-loops consistently generated higher horizontal forces and moments than conventional designs. With 2-mm activation at a 6-mm interbracket distance, the alpha-end horizontal force was 3.29 N in the bidimensional design compared with 2.52 N in the conventional design (∼30% increase). Alpha-end moment-to-force ratios ranged from 4.14-5.58 mm for the bidimensional design vs 3.95-5.11 mm for the conventional design. The 90° torsion bend reduced alpha bracket-slot angular clearance from 3.8° to 0.95°. CONCLUSIONS: Based on theoretical finite element predictions, the bidimensional T-loop design produces greater forces, moments, and alpha-end moment-to-force ratios than conventional T-loops. Reduced alpha-end bracket-slot play may reduce moment attenuation, offering potential biomechanical advantages for maximum-anchorage retraction. These are theoretical mechanical predictions that require clinical and experimental validation before definitive conclusions can be drawn.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Biomechanical Assessment of a Novel Self-Ligating Orthodontic Bracket Using Finite Element Analysis: The LUMACA System.Dentistry journal · 2026
- Effects of clear aligner-assisted miniscrew intrusion in mandibular anterior teeth: a three-dimensional finite element study.BMC oral health · 2026
- Biomechanical evaluation of a customised 3D-printed metal appliance for intrusion of a supra-erupted maxillary second molar: comparative finite element analysis and an illustrative clinical caseBMC Oral Health · 2026
- Combined effects and weight analysis of factors affecting initial maxillary central incisor retraction: a three-dimensional finite element study.Frontiers in bioengineering and biotechnology · 2026
- Finite Element Analysis of Maxillary Molar Intrusion Using Temporary Anchorage Devices: A Comparison of Direct and Indirect Force Loading.Orthodontics & craniofacial research · 2026
- Biomechanical effects of six reverse curve of Spee NiTi archwires: A three-dimensional finite element study.International orthodontics · 2026