Impact of door openings, staff members and operation length on particle contamination and surgical site infections during acute and elective orthopedic implant surgery: an observational study.
Frans Stålfelt, Josefin Seth Caous, Henrik Malchau, Karin Svensson Malchau
Department of Orthopedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden. Electronic address: frans.stalfelt@gmail.com. · Department of Orthopedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden; Department of Methodology, Textiles and Medical Technology, RISE Research Institutes of Sweden, Gothenburg, Sweden.
Key points
From the paper's conclusion- Among 5,105 surgeries, 138 (2.7%) had reported SSI. Each additional person in the OR increased 1.0- and 5.0-µm particle concentrations by 1,503 particles/m³ (95% CI 545-2,462; p=0.002) and 99 particles/m³ (95% CI 34-163; p=0.003), respectively. Staff presence was similar between SSI and non-SSI cases (5.5 vs 5.0). SSI cases had 18-minute longer operative times, 1.5-fold more door openings, and 3.6% higher SSI odds per additional opening.
Abstract
BACKGROUND: Surgical site infection (SSI) is a complication associated with patient morbidity and increased healthcare costs. Its etiology is multifactorial, including intraoperative air contamination. This study aimed to evaluate how door openings and operating room (OR) staff presence, influence particle dispersion during orthopedic implant surgery, and to explore associations with SSI risk. METHOD: Particle counters, door sensors, and camera-based people counting was installed in orthopedic ORs at Sahlgrenska University Hospital, Sweden between 2021 and 2025. Data on reoperations due to SSI were obtained from the Swedish Arthroplasty Register, the Swedish Fracture Register, and a local surgical scheduling system. RESULTS: Among 5,105 surgeries, 138 (2.7%) had reported SSI. Each additional person in the OR increased 1.0- and 5.0-µm particle concentrations by 1,503 particles/m³ (95% CI 545-2,462; p=0.002) and 99 particles/m³ (95% CI 34-163; p=0.003), respectively. Staff presence was similar between SSI and non-SSI cases (5.5 vs 5.0). SSI cases had 18-minute longer operative times, 1.5-fold more door openings, and 3.6% higher SSI odds per additional opening. DISCUSSION AND CONCLUSION: Real-time monitoring provides important insights into intraoperative particle dynamics. Further data are needed to develop robust predictive models for SSI risk and to clarify causal relationships between OR behavior and infection outcomes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Quality Control of Operating Room Traffic by Direct Observation.American journal of infection control · 2026
- Setting limits of airborne microbes during surgery.The Journal of hospital infection · 2026
- Surgical Site Infection: Conditional Influence of Surgery Duration and ASA Classification in Major Procedures.International wound journal · 2026
- Epidemiological patterns, risk factors, and prevention gaps of surgical site infections in operating rooms: a hospital-based surveillance studyFrontiers in Public Health · 2026
- Airborne and Surface Bacteria in ORs: Integration of ASHRAE-Compliant Ventilation and Active UV-C Air Treatment.AORN journal · 2026
- Risk factors for surgical site infection in clean surgeries at a modern small animal teaching hospital-a prospective observational study.Australian veterinary journal · 2026