The American journal of emergency medicine

Comparative safety, efficiency, and diagnostic accuracy of YEARS, PEGeD, age-adjusted D-dimer, and fixed D-dimer strategies for excluding pulmonary embolism in the emergency department: a systematic review and meta-analysis.

Eman E Shaban, Mohammed F Abosamak, Hussam Elmelliti, Ahmed Shaban, Amira Shaban, Afnan W M Jobran, Hany A Zaki

Cardiology Department, Al Jufairi Diagnosis and Treatment, MOH, Doha, Qatar. · Department of Anaesthesia and Intensive Care Medicine, Faculty of Medicine, Tanta University, Egypt; Department of Adults ICU, Security Forces Hospitals Program, General Directorate of Medical Services, Ministry of Interior, Riyadh, Saudi Arabia. Electronic address: Samakawy10@gmail.com.

Meta-analysis

Key points

From the paper's conclusion
  • Across studies, all D-dimer strategies showed high pooled sensitivity, with variable specificity and imaging avoidance rates. Diagnostic failure rates were reported in a limited number of studies, limiting conclusions regarding clinical safety.

Abstract

BACKGROUND: D-dimer-based strategies, including fixed D-dimer, age-adjusted D-dimer (AADD), YEARS, and pulmonary embolism graduated D-dimer (PEGeD), have been developed to exclude pulmonary embolism (PE). This systematic review and meta-analysis compared their diagnostic accuracy, safety, and efficiency in emergency department (ED) patients with suspected PE. METHODS: PubMed, Embase, Web of Science, Scopus, and Cochrane Library were searched from inception to July 2026. Outcomes included diagnostic accuracy (sensitivity and specificity) safety (diagnostic failure rate), and efficiency (imaging avoidance). Bivariate random-effects models were used in pooling diagnostic accuracy outcomes and imaging avoidance rates were expressed as percentages. RESULTS: Twenty-four studies involving 63,583 patients were included. The pooled analysis demonstrated a sensitivity of 98.3% (95% CI, 97.3 to 99.1), 96.5% (95% CI: 94.3 to 98.2), 91.8% (95% CI: 87.2 to 95.4), and 91.0% (95% CI: 79.5 to 95.9), and a pooled specificity of 22.0% (95% CI: 12.8 to 38.8), 34.7% (95% CI: 20.0 to 51.7), 51.6% (95% CI: 32.5 to 71.5), and 43.6 (95% CI: 23.0 to 69.5) for fixed D-dimer, AADD, YEARS, and PEGeD algorithm, respectively. Pooled imaging avoidance rates were 15% (95% CI: 0 to 42) for fixed D-dimer, 16% (95% CI: 0 to 45) for AADD, 51% (95% CI: 23 to 79) for YEARS, and 53% (95% CI: 25 to 81). CONCLUSION: Across studies, all D-dimer strategies showed high pooled sensitivity, with variable specificity and imaging avoidance rates. Diagnostic failure rates were reported in a limited number of studies, limiting conclusions regarding clinical safety.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers