The American journal of emergency medicine

Impact of the provider-in-triage model on computed tomography and ultrasound imaging in renal colic.

Christopher Thom, Colleen Mullins, Benton Spirek, James Moak

University of Virginia Health System, Department of Emergency Medicine, Charlottesville, VA, USA. Electronic address: ct9k@virginia.edu. · University of Virginia Health System, School of Medicine, Charlottesville, VA, USA.

Observational · n=1,041

Key points

From the paper's conclusion
  • PIT exposure was associated with greater CTAP and lower ultrasound utilization in patients with renal colic, including among a prespecified lower-risk cohort. Ultrasound-trained physicians used ultrasound more frequently and CTAP less frequently in renal colic patients.

Abstract

INTRODUCTION: Physician-in-Triage (PIT) models may influence diagnostic imaging decisions in the emergency department (ED). We evaluated the association between PIT exposure and imaging utilization among patients with renal colic and examined the influence of physician ultrasound training on imaging selection. METHODS: We conducted a retrospective cohort study of adults with an ED diagnosis of renal colic at a single tertiary ED from January 2024 through December 2025. A prespecified lower-risk subgroup included patients aged <51 years with prior nephrolithiasis, no infection, and normal creatinine. The primary exposure was PIT evaluation. Outcomes included computed tomography of the abdomen and pelvis (CTAP), point-of-care ultrasound (POCUS), and radiology-performed renal ultrasound (RUS) utilization. Multivariable logistic regression was used to evaluate the association between PIT exposure and each imaging outcome after adjustment for age, gender, emergency severity index, admission, and race. RESULTS: Of 1041 patients, 596 (57.3%) were exposed to PIT. CTAP utilization was higher among PIT-exposed patients than non-PIT patients (72.9% vs 66.1%; adjusted odds ratio [aOR] 1.40, 95% confidence interval [CI] 1.07-1.85). PIT exposure was associated with lower POCUS utilization (10.3% vs 18.6%; aOR 0.49, 95% CI 0.34-0.70), while RUS utilization was similar (10.1% vs 9.0%; aOR 1.17, 95% CI 0.76-1.79). Overall ultrasound utilization (POCUS or RUS) was also lower among PIT-exposed patients (20.1% vs 26.7%; aOR 0.69, 95% CI 0.51-0.93). In the lower-risk subgroup, PIT exposure remained associated with greater CTAP utilization (63.6% vs 48.1%, p = 0.028) and lower POCUS utilization (14.4% vs 30.4%, p = 0.008). Ultrasound-trained attendings used CTAP less frequently than non-ultrasound-trained attendings (57.8% vs 71.8%; aOR for non-ultrasound-trained physicians 1.86, 95% CI 1.18-2.93). CONCLUSION: PIT exposure was associated with greater CTAP and lower ultrasound utilization in patients with renal colic, including among a prespecified lower-risk cohort. Ultrasound-trained physicians used ultrasound more frequently and CTAP less frequently in renal colic patients.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Impact of the provider-in-triage model on computed tomography and ultrasound imaging in renal colic — Science Skim