Department of Respiratory and Critical Care Medicine, the Affiliated Hospital of Inner Mongolia Medical University, Hohhot, 010010, China; Key Laboratory for Biomarkers, Inner Mongolia Medical University, Hohhot, 010010, China. · Center for Clinical Epidemiology Research, the Affiliated Hospital of Inner Mongolia Medical University, Hohhot, 010010, China.

Meta-analysis

Key points

From the paper's conclusion
  • Serum PCT has only moderate diagnostic value for pneumonia-related acute dyspnea and is insufficient to confirm or exclude pneumonia when used alone.

Abstract

BACKGROUND: Several studies have investigated the diagnostic value of serum procalcitonin (PCT) for pneumonia in patients with acute dyspnea, but results have been inconsistent. This systematic review aimed to determine the diagnostic accuracy of serum PCT for pneumonia in patients with acute dyspnea. METHODS: We searched the PubMed and Web of Science databases to identify studies evaluating the diagnostic accuracy of serum PCT for pneumonia-associated acute dyspnea published before October 1, 2025. The quality of the included studies was assessed using the revised Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2). We used a bivariate model to be pooled sensitivity and specificity. The overall diagnostic accuracy was evaluated using a summary receiver operating characteristic curve (sROC). Deek's test was used to assess publication bias. RESULTS: We included 6 studies involving 2341 patients (576 with pneumonia and 1765 without). Serum PCT's pooled sensitivity and specificity for diagnosing pneumonia-related acute dyspnea were 0.67 (95% CI: 0.58-0.75) and 0.76 (95% CI: 0.67-0.83), respectively. The area under the sROC curve (AUC) was 0.77 (95% CI: 0.73-0.80). The positive likelihood ratio (PLR) and negative likelihood ratio (NLR) were 2.8 (95% CI: 2.0-3.8) and 0.44 (95% CI: 0.34-0.56), respectively. The diagnostic odds ratio (DOR) was 6 (95% CI: 4-10). The included studies showed no significant publication bias. CONCLUSIONS: Serum PCT has only moderate diagnostic value for pneumonia-related acute dyspnea and is insufficient to confirm or exclude pneumonia when used alone.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers