Temperature-Heart Rate Coupling Mismatch Index (THRCI) and Its Association with Early Organ Dysfunction and Mortality in Sepsis.
Hui Yang, Junfeng Zhang, Jinzhong Chen, Riming Yuan
Department of Intensive Care Unit, Anting Hospital, Jiading District, Shanghai, China. · Department of Intensive Care Unit, Anting Hospital, Jiading District, Shanghai, China. Electronic address: RimingYuan2365@163.com.
Key points
From the paper's conclusion- Early temperature-heart rate coupling mismatch showed a nominal association with near-term SOFA worsening and may provide incremental prognostic information in sepsis. These exploratory findings require external validation.
Abstract
PURPOSE: Early sepsis risk stratification remains challenging. We hypothesized that abnormal early coupling between body temperature and heart rate reflects physiologic dysregulation and predicts subsequent organ dysfunction. PATIENTS AND METHODS: This single-center prospective cohort at Anting Hospital (March 2021 to September 2025) evaluated adults with Sepsis-3-defined sepsis using a 12-hour landmark design. The Temperature-Heart Rate Coupling Mismatch Index (THRCI) combined four predefined features derived from paired bedside temperature and heart rate data during the first 12 hours. The primary endpoint was a ≥2-point increase in Sequential Organ Failure Assessment (SOFA) score from 12 to 48 hours. Secondary endpoints were new vasopressor use and new invasive mechanical ventilation after 12 hours, and 28-day mortality. Patients who died, were discharged, or were transferred to another institution before the landmark were excluded. Adjusted penalized regression and bootstrap internal validation were used. RESULTS: Of 413 screened patients, 336 were enrolled and 322 analyzed; 108 (33.5%) met the primary endpoint. Each standard-deviation increase in THRCI was nominally associated with higher adjusted odds of SOFA worsening (adjusted odds ratio 2.02, 95% confidence interval 1.12-3.74; p=0.019; false discovery rate-adjusted q=0.06). Adding THRCI increased the apparent area under the receiver operating characteristic curve from 0.71 to 0.78 (optimism-corrected 0.76). Secondary associations were directionally consistent; none of the four associations remained significant after multiplicity adjustment. CONCLUSIONS: Early temperature-heart rate coupling mismatch showed a nominal association with near-term SOFA worsening and may provide incremental prognostic information in sepsis. These exploratory findings require external validation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Body temperature as a dynamic host-response biomarker in sepsis: trajectories and time-varying mortality risk.Frontiers in cellular and infection microbiology · 2026
- Incremental prognostic value of the T-helper 1/T-helper 2 immune phenotype and 72-h change in sequential organ failure assessment for in-hospital mortality in sepsis with and without type 2 diabetes: a retrospective two-cohort study.Frontiers in medicine · 2026
- Early recognition of persistent sepsis-induced coagulopathy burden in critically ill patients with sepsis: trajectory analysis and reduced compatible eICU evaluationThrombosis Journal · 2026
- Body temperature at sepsis recognition as a nursing bedside surveillance parameter: a multicenter observational cohort study.BMC nursing · 2026
- Associations of Heart Rate Trajectories with Mortality and AKI Occurrence in Septic Patients: A Retrospective Study from MIMIC-IV and eICU Databases.Journal of clinical medicine · 2026
- Temporal Analysis of Diastolic Shock Index in Patients with Septic Shock and Its Correlation with Clinical Outcomes in an Indian Setting: A Prospective Observational StudyIndian Journal of Critical Care Medicine · 2026