Comparison of auditory reaction time and sound localization performance across two earphone conditions and a no-earphone condition.
Shomaru Ito, Anna Naito, Kanon Moriue, Yuma Yamaguchi, Risa Hamada, Yusuke Maeda
Department of Physical Therapy, School of Health Sciences at Odawara, International University of Health and Welfare, 1-2-25 Shiroyama, Odawara, Kanagawa, 250-8588, Japan. Electronic address: shomaru.ito5151@gmail.com. · Department of Physical Therapy, School of Health Sciences at Odawara, International University of Health and Welfare, 1-2-25 Shiroyama, Odawara, Kanagawa, 250-8588, Japan.
Key points
From the paper's conclusion- These findings suggest that auditory performance may differ across listening conditions and that the pattern of these differences may vary according to the auditory task.
Abstract
Earphones are widely used during daily activities, raising concerns about their potential influence on the perception of environmental sounds. Rapid detection and accurate localization of surrounding sounds are important for recognizing potential hazards. This within-subject repeated-measures study compared simple reaction time and sound localization performance across no-earphone, canal-type earphone, and bone-conduction earphone conditions in 35 healthy adults (19.7 ± 0.5 years). Music was presented concurrently in the two earphone conditions. Participants performed a simple reaction time task and a sound localization task using a 440-Hz pure tone presented from eight loudspeakers arranged at 45° intervals. Simple reaction time was significantly longer in the canal-type condition than in both the no-earphone and bone-conduction conditions. Sound localization accuracy was significantly lower in both earphone conditions than in the no-earphone condition. Total reversal errors were significantly more frequent in the bone-conduction condition than in the no-earphone condition, and front/rear reversal errors were more frequent in the bone-conduction condition than in both the no-earphone and canal-type conditions. These findings suggest that auditory performance may differ across listening conditions and that the pattern of these differences may vary according to the auditory task. However, because the experimental conditions included concurrent music in the earphone conditions and the use of a single-frequency pure tone for sound localization, the observed differences cannot be attributed solely to earphone type.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Two-dimensional sound localization during hearing protector use: Human performance and acoustic predictionThe Journal of the Acoustical Society of America · 2026
- The level and quality of tinnitus therapy sounds streamed to open-ear hearing aids compared to open-ear earphones in adults with normal-mild hearing lossFrontiers in Audiology and Otology · 2026
- Auditory Spatial Mapping in the Horizontal Plane Using Response Interfaces With Different Curvatures.Trends in hearing · 2026
- EarLog: Opportunistic Ear Physiology Sensing toward Personalized Hearing Risk AwarenessarXiv · 2026
- Listening Effort in Complex Audiovisual Scenes Under Varying Simulated Room Acoustic Conditions.Trends in hearing · 2026
- Cognitive consequences of background noise: integrating irrelevant sound effect, listening effort, and working memoryThe Egyptian Journal of Otolaryngology · 2026