Acta biomaterialia

Viscoelastic, fatigue, and tensile response of scaffold-free, self-assembled dermal fibroblast tissue rings.

Nicholas Nocevski, Madeleine Marx, Vikas Srivastava, Jeffrey R Morgan

Department of Pathology and Laboratory Medicine; Center for Alternatives to Animals in Testing; School of Engineering Brown University, Providence, RI, USA. · Department of Pathology and Laboratory Medicine; Center for Alternatives to Animals in Testing.

Review

Key points

From the paper's conclusion
  • Our data indicate that ring tissues are biomechanically comparable to early-stage healing connective tissues and exceed benchmarks for non-cross linked collagen hydrogels.

Abstract

Scaffold-free, self-assembled, in vitro tissues hold promise for disease modeling and connective tissue engineering, but their mechanical characterization has been limited to static/quasi-static measures. Viscoelasticity and cyclic fatigue are key to tissue performance in vivo. This study aims to determine how well ring-shaped tissues mechanically reflect these properties. Ring-shaped tissues were generated by seeding human fibroblasts into non-adherent agarose molds to direct tissue formation and de novo ECM synthesis. Strain hardening, fatigue, and stress relaxation testing were performed on ring tissues. Durability was assessed via S-N curve construction and collagen damage was visualized via collagen hybridizing peptide (CHP) staining. Finally, finite element analysis (FEA) simulations were used to develop a viscoelastic and fibrous model of the tissue. Stress at break increased 67.8% over a strain-rate range from 0.1 %/s to 10 %/s, and tissues relaxed by 55.0% under fixed stretch, indicating a degree of relaxation consistent with natural collagenous tissues. Rings survived thousands of cycles during cyclic fatigue, with a 10-fold increase of fatigue life for each 5.9 percentage points decrease in stress amplitude (95% CI: 4.8 - 7.0 percentage points). FEA results achieved R2 of 0.991 to force-displacement response. The collective results position the ring tissues as a promising biomaterial, comparable to early-stage, healing load-bearing connective tissues of the body and exceeding collagen hydrogels that have not been chemically cross linked. While not matching the mechanical properties of mature ligament or tendon, we discuss current uses of the model and future directions for development towards applications in regenerative medicine and therapeutic screening. STATEMENT OF SIGNIFICANCE: Fatigue life, viscoelasticity, and non-linear constitutive parameters of scaffold-free cultured ring tissues that synthesize a collagenous ECM de novo have not been defined. This is despite the determining role these traits play for in vivo performance. We characterized these emergent mechanical properties in engineered connective tissue grown in the absence of traditional scaffolds. Further, we developed and implemented a modeling pipeline and found that in vitro ring tissues show hallmarks of native connective tissues. Our data indicate that ring tissues are biomechanically comparable to early-stage healing connective tissues and exceed benchmarks for non-cross linked collagen hydrogels. This presents a mechanistic characterization framework that can be applied for further development of ring tissues for drug screening and applications in regenerative medicine.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Viscoelastic, fatigue, and tensile response of scaffold-free, self-assembled dermal fibroblast tissue rings — Science Skim