Computational Modeling of Bioresorbable Flow-Diverting Stents: Insights into Approaches for Coupling Hemodynamics and Material Degradation.
Ashley Taepakdee, Skylar McDonald, Zachary Molander, Geoffrey P Colby, Victor G J Rodgers, Gerhard A Holzapfel, Chung-Hao Lee
Biomechnics and Biomaterials Design Laboratory, Department of Bioengineering, The University of California, Riverside, Riverside, CA 92507, USA. · Department of Neurosurgery, University of California, Los Angeles, Los Angeles, CA 90095, USA.
Key points
From the paper's conclusion- Additionally, since no standardized validation protocol currently exists for computational models of BRFDs, we recommend a staged pathway: a framework integrating material degradation and hemodynamics and considering thrombosis and endothelialization, validated against in vitro and/or in vivo data, will be essential for advancing the design and therapeutic efficacy assessment of BRFDs.
Abstract
Bioresorbable flow diverters (BRFDs) represent an emerging treatment for intracranial aneurysms (IAs) that reduces complications associated with permanent flow diverters, as BRFDs-due to their temporary nature-restore native blood flow following degradation. The therapeutic efficacy of BRFDs depends on material degradation, hemodynamics, thrombosis, and endothelialization. To this end, computational models enabling a holistic evaluation of the interplay between these processes could provide considerable insight into optimized BRFD designs. This review summarizes degradation modeling approaches for bioresorbable metals, including continuum damage mechanics (CDM), mechanochemical phase-field, and reaction-diffusion models. It evaluates the suitability of each framework for integration with computational fluid dynamics (CFD) for guiding BRFD design. CDM approaches focus on the degradation of mechanical integrity and do not directly consider electrochemical transport, whereas mechanochemical models account for mechanical, chemical, and electrochemical processes, providing detailed information on localized corrosion, albeit at a higher computational cost. Reaction-diffusion models are the most practical option for coupling with CFD, offering a balance between accuracy in describing key mechanisms and computational feasibility, although the most suitable approach ultimately depends on how each metal degrades. Critical gaps in BRFD models include the limited modeling of iron, zinc, and molybdenum, and specific aspects of blood chemistry. Additionally, since no standardized validation protocol currently exists for computational models of BRFDs, we recommend a staged pathway: a framework integrating material degradation and hemodynamics and considering thrombosis and endothelialization, validated against in vitro and/or in vivo data, will be essential for advancing the design and therapeutic efficacy assessment of BRFDs. STATEMENT OF SIGNIFICANCE: Bioresorbable flow diverters (BRFDs), when compared to permanent flow diverters, allow mitigation of long-term complications in treating intracranial aneurysms, but their development remains limited by an incomplete understanding of the interaction between material degradation, blood flow, and biological responses such as thrombosis and aneurysm healing. The design choices of FDs ultimately depend on this interplay, yet no computational framework currently exists to guide it. This review is the first of its kind to systematically evaluate the use of degradation models for coupling with computational fluid dynamics (CFD) to elucidate physiologically relevant information of aneurysm healing with BRFDs. Coupling these frameworks provides a practical guide to accelerate the translation of bioresorbable devices from conceptualization, design, and development to clinical use.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Hemodynamic-Structural Multi-Fidelity Assessment of Endovascular Flow Diversion Strategies for Cerebral Aneurysm Treatment: An Integrated Computational and Experimental FrameworkbioRxiv · 2026
- Patient-Specific Hemodynamic and Angiographic Evaluation of a Novel Flow-Diverting Device for Intracranial Aneurysms.Bioengineering (Basel, Switzerland) · 2026
- A Comparative Analysis of Stent Performance in Aneurysm: Impact of Newtonian and Non-Newtonian Flow DynamicsSciEn Conference Series Engineering · 2026
- Modeling Perforator Occlusion After Flow Diversion.International journal for numerical methods in biomedical engineering · 2026
- From Device Modeling to Blood Flow Simulation: A Study of the Woven EndoBridge.International journal for numerical methods in biomedical engineering · 2026
- Computational Modeling of Thoracic Aortic Stent-Grafts: Bibliometric Analysis and Current TrendsComputation · 2026