Large Language Models and a Recently Revised Radiology Classification: Modified CIRSE Grading With and Without Current Criteria.
Oğuzhan Türksayar, Hamit Özgül, Ali Dablan, Mustafa Fatih Arslan, Çağrı Erdim, Mehmet Cingöz, Tevfik Güzelbey, Özgür Kılıçkesmez
Department of Radiology, Başakşehir Çam and Sakura City Hospital, Istanbul, Türkiye (O.T., A.D., M.F.A., Ç.E., and M.C.). Electronic address: oguzhanturksayar@gmail.com. · Department of Radiology, Bağcılar Training and Research Hospital, Istanbul, Türkiye (H.Ö.).
Key points
From the paper's conclusion- Exact-grade accuracy was higher in all four models when the current criteria were supplied. In a post hoc descriptive analysis, complete exact-grade failure was confined to newly subdivided grades. Current classification criteria should be supplied explicitly for model-based complication grading.
Abstract
RATIONALE AND OBJECTIVES: Recently revised professional classifications may create a version mismatch for large language models, as plausible responses can reflect a superseded rather than the current schema. The modified Cardiovascular and Interventional Radiological Society of Europe classification, which subdivided Grades 1 and 3, provided a controlled setting to examine this problem. We evaluated four large language models with and without the current criteria supplied in the prompt. MATERIALS AND METHODS: Sixty-four purpose-written vignettes, eight per category, were independently graded by two interventional radiologists, with consensus serving as the reference standard. Four models (gpt-5.6-sol, claude-sonnet-5, gemini-3.8-flash, and deepseek-flash) were queried under closed-book and guideline-augmented conditions three times per vignette, yielding 1536 requests. The primary outcome was run-1 exact-grade accuracy, compared within models using Holm-adjusted McNemar tests. RESULTS: Closed-book exact-grade accuracy ranged from 15 of 64 to 31 of 64, whereas all four models achieved 64 of 64 with the criteria supplied. All Holm-adjusted p values were <0.001. In a post hoc descriptive analysis, exact-grade accuracy was 0 of 128 classifications in the newly subdivided grades and 99 of 128 in grades retaining established labels. None of the four new subclass labels appeared in any of the 256 run 1 closed-book responses. Across all three closed-book runs, superseded grades accounted for 36.5% of responses. CONCLUSION: Exact-grade accuracy was higher in all four models when the current criteria were supplied. In a post hoc descriptive analysis, complete exact-grade failure was confined to newly subdivided grades. Current classification criteria should be supplied explicitly for model-based complication grading.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Insufficient reporting quality in large language model studies in the field of radiologyInsights into Imaging · 2026
- Large language model assistance for report-based carotid plaque AHA classification: a multi-reader study.Insights into imaging · 2026
- Reproducibility and guideline concordance of next-generation large language models on ESE S3-based endodontic questions: a multi-account, multi-timepoint evaluation.Odontology · 2026
- Guideline-augmented large language models for contraindication screening in interventional spine care.Interventional pain medicine · 2026
- Generating occlusion clinical cases with large language models: a comparative evaluation of claude, gemini, and qwen in undergraduate dental education.Frontiers in medicine · 2026
- Comparative accuracy of large language models and orthopaedic clinicians in knee osteoarthritis and tibial plateau fracture classification systems.The Knee · 2026