Academic radiology

Semi-automated Quantitative Assessment of Radiology Resident Reporting Performance Using Large Language Models: A Pilot Study.

Gabriela Hossu, Sébastien Aubry, Timothée Zaragori, Marc Braun, Pedro Gondim Teixeira

Université de Lorraine, Inserm, IADI, Nancy, France (G.H., T.Z., M.B., P.G.T.); CHRU-Nancy, Inserm, Université de Lorraine, CIC, Innovation Technologique, Nancy, France (G.H., T.Z.). Electronic address: g.hossu@chru-nancy.fr. · CIMRAD, Besançon, France (S.A.).

Key points

From the paper's conclusion
  • The proposed framework provides a structured and reproducible approach for quantitative assessment of radiology resident reporting performance. These preliminary findings support feasibility and warrant larger multicenter validation before educational deployment.

Abstract

RATIONALE AND OBJECTIVES: To evaluate a semi-automated large language model (LLM)-based scoring pipeline to quantify diagnostic agreement between radiology residents' preliminary and expert-validated final reports. MATERIALS AND METHODS: Sixty-eight paired reports from six radiology residents at a single-center were processed through a two-step pipeline: LLM-based data extraction followed by expert validation and LLM scoring. GPT-5 served as the primary model with full intra-rater and inter-rater reproducibility analyses (35 and 68 pairs, respectively); GPT-4 served as the secondary model. Three metrics were computed: Global Obtained Score (GOS), Global Expected Score (GES), and Clinical Similarity Index (CSI). Agreement was assessed using intraclass correlation coefficients (ICC, two-way random, absolute agreement) and Bland-Altman analysis. A discordance review was performed on 22 report pairs with absolute CSI differences >0.10. RESULTS: GPT-5 achieved good-to-excellent intra-rater reproducibility (ICC: GOS 0.91, GES 0.99, CSI 0.88), comparable to expert scoring (0.93, 0.98, 0.82). Agreement between GPT-5 and the expert was good for GOS (ICC 0.88), excellent for GES (0.98), and moderate-to-good for CSI (0.75). CSI agreement improved from ICC 0.52 (GPT-4) to 0.75 (GPT-5), with a 28% reduction in Bland-Altman limits of agreement. Inter-human agreement on a discordant-enriched subset was moderate to good (ICC: GOS 0.83, GES 0.85, CSI 0.71). Discordance analysis identified five recurring error categories and one hallucination. In 7/30 (23.3%) reviewed disagreements, the expert retrospectively agreed with GPT-5 scoring, including clinically impactful discrepancies initially overlooked during expert scoring. CONCLUSION: The proposed framework provides a structured and reproducible approach for quantitative assessment of radiology resident reporting performance. These preliminary findings support feasibility and warrant larger multicenter validation before educational deployment.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers