Academic radiology

Reporting of Fairness and Equity in Studies of Regulator-cleared Commercial AI for Acute Stroke CT: A Systematic Review.

Yosef Adiniaev, Mahmud Omar, Tohar M Timor, Oved Daniel, Yonatan Adiniaev, Yiftach Barash, Olga R Brook, Eyal Klang,

Faculty of Medicine, University of Debrecen, Debrecen, Hungary (Y.A., T.M.T., Y.A.); BRIDGE GenAI Lab, Beth Israel Deaconess Medical Center, Boston, MA, USA (Y.A. M.O., Y.B., E.K., A.G.). Electronic address: yosefad1305@gmail.com. · BRIDGE GenAI Lab, Beth Israel Deaconess Medical Center, Boston, MA, USA (Y.A. M.O., Y.B., E.K., A.G.); The Windreich Department of Artificial Intelligence and Human Health, Mount Sinai Medical Center, New York, NY, USA (M.O.); The Hasso Plattner Institute for Digital Health at Mount Sinai, Mount Sinai Health System, New York, NY, USA (M.O.).

Review

Key points

From the paper's conclusion
  • Subgroup performance was rarely reported in the included peer-reviewed evaluations. The finding of positive predictive value differences in one study is insufficient to characterize fairness across products. Missing subgroup and training-population reporting limits assessment of fairness, but does not establish that the evaluated systems are inequitable.

Abstract

RATIONALE AND OBJECTIVES: Commercial artificial intelligence (AI) tools cleared by regulators now triage acute stroke on computed tomography (CT) scans across health systems whose patients differ in age, sex, race, socioeconomic status, and imaging hardware. It is unknown whether studies of these tools report how performance varies across such groups. MATERIALS AND METHODS: We systematically reviewed English-language studies of commercial, regulator-cleared AI tools for adult acute stroke CT tasks. PubMed, Scopus, and PubMed Central were searched from January 1, 2018, through June 2, 2026, and Embase, Web of Science Core Collection, and IEEE Xplore were searched on September 14, 2026, for records published from 2018 onward; the searches were supplemented by a backward-reference and forward-citation audit. Two reviewers independently screened studies, extracted data, and assessed risk of bias. Eight prespecified reporting items informed by CLAIM 2024, TRIPOD+AI, and evidence on algorithmic bias were scored as reported, partial, or not reported. The review was registered with PROSPERO (CRD420261403480). RESULTS: Thirteen studies covering nine vendors and four CT tasks met the eligibility criteria. Only one study reported sociodemographic subgroup performance. It found lower positive predictive value for female patients than for male patients (67.3% vs. 72.7%; p = 0.02) and for Black patients than for non-Black patients (66.7% vs. 73.2%; p = 0.005). Performance by site, scanner, or protocol was reported in one other study. No included peer-reviewed study described the demographic composition of the tool's training data, and four studies acknowledged a potential bias or data gap without measuring it. CONCLUSION: Subgroup performance was rarely reported in the included peer-reviewed evaluations. The finding of positive predictive value differences in one study is insufficient to characterize fairness across products. Missing subgroup and training-population reporting limits assessment of fairness, but does not establish that the evaluated systems are inequitable.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Reporting of Fairness and Equity in Studies of Regulator-cleared Commercial AI for Acute Stroke CT: A Systematic Review — Science Skim