Automated Structured Reporting of Neurodegenerative Imaging Markers Using Quantitative MRI and Large Language Models.
Ji Su Ko, Wooseok Jung, Pae Sun Suh, Hwon Heo, Woo Hyun Shim, Dong-Hee Kim, Seung Hyun Lee, Mijoo Kim,
Department of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea (J.S.K.). · VUNO Inc, Seoul, Republic of Korea (W.J., D.-H.K., S.H.L., M.K., N.L., S.K.); UC Berkeley-UCSF Graduate Program in Bioengineering, University of California, San Francisco, San Francisco, California (W.J.).
Key points
From the paper's conclusion- Our quantitative MRI-to-structured reporting pipeline, integrating quantitative MRI software with LLM-based conclusion generation, might be feasible for automated structured drafting of neurodegenerative imaging markers.
Abstract
RATIONALE AND OBJECTIVES: To evaluate the feasibility of a quantitative magnetic resonance imaging (MRI)-to-structured reporting pipeline that integrates quantitative MRI software with large language models (LLMs) for structured drafting of neurodegenerative imaging markers and generating clinician-facing report conclusions. MATERIALS AND METHODS: A total of 192 patients with 3D T1 and 2D or 3D FLAIR MRI images from the Alzheimer's Disease Neuroimaging Initiative database were randomly selected. A deep-learning model generated structured report findings based on nine indices related to brain atrophy, white matter hyperintensities, and cerebrospinal fluid (CSF) space abnormalities, and compared with neuroradiologist-generated reference reports. Four LLMs (GPT-OSS 20B, MedGemma 4B, Phi-3, and Llama 3.1 8B) generated clinician-facing conclusions from the structured findings. Generated conclusions were evaluated using a five-point Likert scale across four metrics (accuracy, relevance, clarity, and satisfaction). Output errors were assessed across four categories: language, omission, addition, and numeric errors. RESULTS: Structured report findings demonstrated high accuracy for CSF space analysis (77.6%-97.9%). Performance for ordinal visual scales was lower under strict matching (27.1%-57.8%) but improved with a one-grade tolerance (91.7%-97.4%). Among LLMs, GPT achieved the highest scores across most metrics (median score 5) and exhibited the lowest output error rates. Smaller models (Phi-3 and Llama 3.1 8B) showed overall lower performance, with more language, omission, and addition errors. MedGemma demonstrated intermediate performance, but the highest rate of numeric errors. CONCLUSION: Our quantitative MRI-to-structured reporting pipeline, integrating quantitative MRI software with LLM-based conclusion generation, might be feasible for automated structured drafting of neurodegenerative imaging markers.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Automatic extraction of structured information from brain MRI reports using an open-weight large language model.European radiology · 2026
- Comparative Evaluation of Open-Weight Large Language Models for Pathological Brain MRI Reports Classification: From Prompts to a Fine-Tuned Model.Academic radiology · 2026
- Heterogeneity in Multimodal AI Feature Engineering Utility for Explaining Change in Dementia2026
- Large language model consensus for reliable research cohort construction from radiology reports: a retrospective cohort study.medRxiv : the preprint server for health sciences · 2026
- ADGPT: A Prior-Guided and GPT-Empowered Framework for MRI-Based Alzheimer's Disease Diagnosis.Journal of imaging informatics in medicine · 2026
- A Reproducible Decomposed Large Language Model Pipeline for Structured Abstraction of Multimodal Neuroimaging Reports: Development and Independent Validation in 1,669 Emergency Department Encounters for Dizziness and VertigomedRxiv · 2026