Department of Ultrasound, First Affiliated Hospital, Third Military Medical University (Army Medical University), Chongqing, China (L.L., Y.T., C.T., P.C., K.C., Y.W., Y.T., W.W., L.T., Y.G.); Department of Digital Medicine, School of Biomedical Engineering and Medical Imaging, Third Military Medical University (Army Medical University), Chongqing, China (L.L.). · Department of Ultrasound, First Affiliated Hospital, Third Military Medical University (Army Medical University), Chongqing, China (L.L., Y.T., C.T., P.C., K.C., Y.W., Y.T., W.W., L.T., Y.G.).

Observational · n=815

Key points

From the paper's conclusion
  • A study-derived modification of CEUS LI-RADS incorporating AFP >20 ng/mL (LR-5++) improved diagnostic performance for sHCC in this cohort, addressing the limitated sensitivity of the standard algorithm.

Abstract

RATIONALE AND OBJECTIVES: We aimed to validate and optimize the contrast-enhanced ultrasound (CEUS) Liver Imaging Reporting and Data System (LI-RADS) for diagnosing small hepatocellular carcinoma (sHCC; ≤ 30 mm) in a Chinese expanded high-risk population: a viral-related liver disease or cirrhosis (VC) group, and a non-VC group with non-cirrhotic, non-viral liver disease, including alcohol-related liver disease and metabolic dysfunction-associated steatotic liver disease. MATERIALS AND METHODS: This multicenter study included 856 liver nodules (≤ 30 mm) from 815 patients, divided into retrospective derivation and prospective validation cohorts. CEUS LI-RADS v2017 was applied, then optimized by (1) tightening the early-washout cutoff from < 60 s to < 50 s, reclassifying LR-M lesions with washout onset from 50 to < 60 s as LR-5+; and (2) integrating serum alpha-fetoprotein (AFP) > 20 ng/mL, reclassifying LR-4/LR-M nodules as LR-5++. Standard and optimized criteria were compared using accuracy, sensitivity, specificity, and positive predictive value (PPV). RESULTS: Across cohorts, standard LR-5 showed high specificity (87.67-93.01%) but suboptimal sensitivity (57.69-64.41%). In the validation cohort, LR-5++ significantly improved sensitivity from 57.69% to 71.43% (P < 0.05) and accuracy from 73.23% to 80.31% (P < 0.05), while specificity decreased slightly from 93.01% to 91.61% without reaching statistical significance. In subgroup analysis, LR-5++ improved sensitivity in both subgroups, most markedly in the VC group. CONCLUSION: A study-derived modification of CEUS LI-RADS incorporating AFP >20 ng/mL (LR-5++) improved diagnostic performance for sHCC in this cohort, addressing the limitated sensitivity of the standard algorithm.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers