Intraoperative ventilatory settings during abdominal surgery among 1,091 anesthesia providers.
Audrey De Jong, Karubandika Kavugho, Alina Kozoriz, Mathieu Capdevila, Joris Pensier, Clément Monet, Yassir Aarab, Ines Lakbar,
PhyMedExp, University of Montpellier, INSERM, CNRS, CHU Montpellier, Département d'Anesthésie-Réanimation, Hôpital Saint-Eloi, 80 avenue Augustin Fliche, 34295 Montpellier cedex, France. · Département d'Anesthésie-Réanimation, Hôpital Saint-Eloi, 80 avenue Augustin Fliche, 34295 Montpellier cedex, France.
Key points
From the paper's conclusion- In this nationwide survey, expert consensus-based recommendations for protective ventilation during abdominal surgery appeared widely implemented in France. In contrast, individualized PEEP strategies were reported in fewer than half of cases, reflecting ongoing uncertainty and variability regarding PEEP titration in routine perioperative practice.
Abstract
BACKGROUND: Data are lacking regarding current ventilatory settings during abdominal surgery. Expert recommendations emphasize the need for protective ventilation, and several tools are now available to individualize positive end-expiratory pressure (PEEP). METHODS: We conducted a nationwide cross-sectional survey among French anesthesiologists and nurse anesthetists in November 2025 to assess ventilatory settings during abdominal surgery, both for laparotomy and laparoscopy. Protective ventilation was defined as the combination of low tidal volume (6-8 mL/kg predicted body weight), low-to-moderate PEEP (5-8 cm H2O), and recruitment maneuvers. Individualization of PEEP was defined as the use of driving pressure, mechanical power, or compliance to titrate PEEP. RESULTS: Among 1091 anesthesiologists and nurse anesthetists, female responders accounted for 46% (497/1084), the median age of anesthesia providers was 39 (33-47) years, and most responders (77%, 839/1090) had an adult-based main field of activity. Main ventilatory settings used during laparotomy were 6 to 8 ml/kg of predicted body weight (93%, 1013/1084), a respiratory rate set according to EtCO2 in 53% of responders (579/1084), and a PEEP set between 5 and 8 cmH20 for 87% of responders (950/1091). Most participants performed recruitment maneuvers (98%, 1065/1091). Overall, protective ventilation was used in 70% (763/1090), and individualization of PEEP in 45% (479/1054). Similar ventilatory settings were reported for laparoscopy. CONCLUSIONS: In this nationwide survey, expert consensus-based recommendations for protective ventilation during abdominal surgery appeared widely implemented in France. In contrast, individualized PEEP strategies were reported in fewer than half of cases, reflecting ongoing uncertainty and variability regarding PEEP titration in routine perioperative practice.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Ventilation distribution assessed by electrical impedance tomography during robot-assisted laparoscopic prostatectomy: A randomized controlled trial.Medicine · 2026
- Individualized Positive End-Expiratory Pressure and Postoperative Pulmonary Outcomes in Laparoscopic and Robotic Abdominal-Pelvic Surgery: A Systematic Review and Meta-Analysis.Cureus · 2026
- Inter‐Individual Variation in LUNG Mechanics Assessed by the Non‐Invasive PEEP ‐Step Method During Laparoscopic and Robotic Surgery Indicates Need for Individualized Ventilatory SettingsActa Anaesthesiologica Scandinavica · 2026
- Intraoperative ventilation settings in Germany: an observational multicentre cross-sectional study.Canadian journal of anaesthesia = Journal canadien d'anesthesie · 2026
- Intraoperative Driving Pressure–Guided High PEEP vs Standard Low PEEP for Postoperative Pulmonary ComplicationsJAMA · 2025
- Expert recommendations for setting and adjusting airway pressure release ventilation based on clinical experience and basic science evidenceFrontiers in Medicine · 2026