Anais brasileiros de dermatologia

Low-level laser therapy for treating pressure ulcers: a systematic review and meta-analysis.

Thiago Chaves Amorim, Isabela Dantas Bezerra Amorim, Ciro Martins Gomes, Elisete Isabel Crocco

Department of Dermatology, Faculdade de Ciências Médicas, Santa Casa de São Paulo, São Paulo, SP, Brazil. Electronic address: thiago@institutocdt.com.br. · Department of Physical Medicine and Rehabilitation, Faculty of Medicine, Universidade de São Paulo, São Paulo, SP, Brazil.

Meta-analysis

Key points

From the paper's conclusion
  • True laser LLLT was associated with improved healing and excellent safety; however, it rests on three small trials with a lower confidence bound approaching no effect, warranting caution. The coherent-laser versus LED distinction merits confirmation in adequately powered trials.

Abstract

BACKGROUND: Pressure ulcers are prevalent and burdensome. Low-Level Laser Therapy (LLLT) is a proposed photobiomodulation adjunct, but evidence is contested, and coherent lasers are frequently pooled with non-coherent Light-Emitting Diode (LED) sources. OBJECTIVES: To synthesize Randomized Controlled Trial (RCT) evidence on LLLT and LED phototherapy for pressure ulcer healing, distinguishing true laser from combined (laser-plus-LED) photobiomodulation. METHODS: Four databases were searched through January 2025. RCTs of LLLT or LED phototherapy versus standard care or sham in adults with pressure ulcers were eligible. Risk of bias used RoB2; complete healing was pooled as Risk Ratios (RR) using random-effects models, with GRADE certainty. Reporting followed PRISMA 2020 (PROSPERO CRD42025631008). RESULTS: Thirteen RCTs (779 participants) were included. Combined photobiomodulation (4 studies, 353 participants) showed no benefit (RR = 1.34; 95% CI 0.84-2.12; p = 0.22; I² = 58%). True laser LLLT (3 studies, 190 participants) improved healing (RR = 1.62; 95% CI 1.07-2.44; p = 0.02; I² = 1%; Number Needed to Treat [NNT] = 5, 95% CI 3-18). Adverse events were mild (∼3%). STUDY LIMITATIONS: Small samples, methodological heterogeneity, variable follow-up (4-12 weeks), and blinding challenges; only two trials were low-risk, and the significant subgroup's significance was not robust to leave-one-out testing. GRADE certainty was moderate (true laser) and low (combined). CONCLUSIONS: True laser LLLT was associated with improved healing and excellent safety; however, it rests on three small trials with a lower confidence bound approaching no effect, warranting caution. The coherent-laser versus LED distinction merits confirmation in adequately powered trials.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers