Annals of anatomy = Anatomischer Anzeiger : official organ of the Anatomische Gesellschaft

Level-specific morphometry of the cervical laminae and zygapophysial joints for posterior laminoforaminotomy: a combined computed tomography, magnetic resonance imaging and anatomical donor study.

Boran Urfalı, İlkan Tatar

Department of Neurosurgery, Tayfur Ata Sökmen Faculty of Medicine, Hatay Mustafa Kemal University, 31060, Antakya, Hatay, Türkiye; Department of Anatomy, Hacettepe University Faculty of Medicine, 06230, Altındağ, Ankara, Türkiye. Electronic address: burfali@mku.edu.tr. · Department of Anatomy, Hacettepe University Faculty of Medicine, 06230, Altındağ, Ankara, Türkiye.

Key points

From the paper's conclusion
  • Routine CT and MRI measurements are not interchangeable in the individual patient, and dimensions that set drilling depth and facetectomy extent are better taken from CT. The 5-mm value is half of a mean dimension, not a validated safe resection distance or an operative target.

Abstract

BACKGROUND: Posterior cervical laminoforaminotomy passes between the laminae and the medial zygapophysial (facet) joints, where safe bone removal is measured in millimeters. The poor depiction of cortical bone on conventional magnetic resonance imaging (MRI) is well known, but its size relative to computed tomography (CT) has not been quantified for each dimension and level. METHODS: Fifty adults (25 women, 25 men; mean age 48.1±14.4 years) with routine cervical CT and MRI within 30 days were studied. One observer measured laminar, facet joint and articular process dimensions bilaterally from C2 to C7; agreement was assessed with intraclass correlation coefficients (ICC). Eight fresh-frozen anatomical donors were dissected and measured as a separate anatomical reference. RESULTS: MRI values were lower than CT values for articular process thickness at every joint (by 0.9-1.7mm) and for lamina thickness at most levels (by up to 1.2mm at C2; C4 excepted). Agreement was poor to moderate for every parameter (ICC 0.001-0.71), highest for lamina height and facet joint length. Half of the mean CT facet joint length was 4.9-5.4mm at each joint, 4.2-5.0mm in women, and an estimated 2.4-2.6mm at the 5th percentile at C7-T1. Lamina height and facet joint length were greater in men at all levels. CONCLUSIONS: Routine CT and MRI measurements are not interchangeable in the individual patient, and dimensions that set drilling depth and facetectomy extent are better taken from CT. The 5-mm value is half of a mean dimension, not a validated safe resection distance or an operative target.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers