Reliability of Clinical Oculomotor Tests in Children and Young Adults Following Moderate-Severe Traumatic Brain Injury.
Gilad Sorek, Liran Kalderon, Aurélie Garat, Eloïse Chesson, Isabelle Gagnon, Kathryn Schneider, Michal Katz-Leurer, Mathilde Chevignard
Department of Physical Therapy, Faculty of Health Sciences, Ariel University, Ariel, Israel. giladso@ariel.ac.il. · Department of Physical Therapy, Faculty of Health Sciences, Recanati School for Community Health Professions, Ben-Gurion University of the Negev, Beer-Sheva, Israel.
Key points
From the paper's conclusion- In-person ratings of standardised clinical OM tests demonstrated almost perfect inter-rater agreement, supporting their use in clinical practice following msTBI. However, video-based assessments show low reliability and require careful consideration and potentially modified protocols.
Abstract
PURPOSE: To assess the inter- and intra-rater reliability of clinical oculomotor (OM) testing using in-person and video assessments of individuals following moderate-severe Traumatic-Brain-Injury (msTBI). METHODS: Thirty-two individuals aged 18.6 ± 7.6 years [range 7-35.5 years] following msTBI (50% adults, 81% males) participated. Clinical OM tests included evaluation of smooth-pursuit, saccades, near-point-convergence (NPC) and gaze-evoked-nystagmus (GEN). Each test was rated as normal/abnormal. The tests were performed in-person by two investigators (in-person inter-rater). One of the investigators also captured a video recording of the eye movements, which was scored offline by two additional investigators (video inter-rater). In addition, one of the investigators re-scored the video recording (video intra-rater). The first in-person and video assessments were compared (in-person-to-video inter-rater). RESULTS: Observed agreement between in-person raters was very high and all tests showed almost perfect reliability (k > 0.93, p < 0.001). The video inter-rater agreement was moderate (43.7-65.6%); only the NPC was significantly reliable (k = 0.44, p = 0.02). The video intra-rater agreement was fair-substantial (65.6-81.2%; k = 0.38-0.74, p < 0.02). The in-person-to-video inter-rater reliability was only moderate (<62.5%) and none of the tests were significantly reliable. CONCLUSION: In-person ratings of standardised clinical OM tests demonstrated almost perfect inter-rater agreement, supporting their use in clinical practice following msTBI. However, video-based assessments show low reliability and require careful consideration and potentially modified protocols. GOV IDENTIFIER: NCT03215082; registration date: 09/07/2017.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Developmental eye movement test performance and oculomotor dysfunction in adults with chronic mild traumatic brain injury.Brain injury · 2026
- Diagnostic accuracy of objective measures for ocular malingering: A systematic review.Journal of optometry · 2026
- Demographics-robust spontaneous eye blinking slowing in patients with severe acquired brain injury.Neuroscience of consciousness · 2026
- Objective oculomotor, vestibular, reaction time, and cognitive signatures of vestibular migraineFrontiers in Neurology · 2026
- Sports-related suspected head injury is associated with otolith-mediated ocular misalignment.Frontiers in neurology · 2026
- Examining reaction time variables to detect invalid performance on the TOMM 2: comparing mTBI to simulators using two procedures.Journal of clinical and experimental neuropsychology · 2026