Efficacy and Safety of Specialty-Designed Orthokeratology Lenses with a Reduced Corneal Central Zone Moulding Area in Children with Low Myopia: A Prospective, Randomised, Controlled Trial.
Qi Zhang, Changliang Peng, Yishu Wang, Chen Chu, Tao Yu, Jianfeng Zhu
Shanghai Eye Diseases Prevention & Treatment Centre/Shanghai Eye Hospital, School of Medicine, Tongji University, National Clinical Research Centre for Eye Diseases; Shanghai Engineering Research Centre of Precise Diagnosis and Treatment of Eye Diseases; Eye Public Health Research Centre, School of Medicine, Tongji University, Shanghai, China. · Department of Spinal Surgery, The Second Qilu Hospital of Shandong University, Jinan, China.
Key points
From the paper's conclusion- Participants were randomly assigned (1:1) to wear either standard-design ortho-k lenses or specialty-designed ortho-k lenses designed to produce a reduced corneal central zone moulding area for 12 months.
Abstract
PURPOSE: Orthokeratology (ortho-k) is widely used for myopia control in children. Specialty-designed ortho-k lenses with a modified corneal reshaping profile may offer an alternative approach for myopia control through altered lens design characteristics. This study aimed to evaluate the efficacy and safety of this lens design in slowing axial elongation and myopia progression in children with low myopia, and to explore ocular structural predictors of the treatment response. METHODS: This prospective, randomised, double-masked clinical trial enroled 80 children aged 8-14 years with low myopia (-1.00 to -3.00 D). Participants were randomly assigned (1:1) to wear either standard-design ortho-k lenses or specialty-designed ortho-k lenses designed to produce a reduced corneal central zone moulding area for 12 months. Axial length was measured at baseline and at 1, 3, 6, 9 and 12 months. The primary outcome was the change in axial length (ΔAL) over time. Secondary outcomes included changes in spherical equivalent refraction (SER) and adverse events. RESULTS: The mean base curve squared (BC2), representing the estimated corneal central zone moulding area, was 8.73 ± 5.59 mm2 in the test group, which was significantly smaller than that in the control group (11.21 ± 5.17 mm2; t = 2.685, p = 0.008). Compared with the control group, the values of ΔAL at month 6 (0.103 ± 0.14 vs. 0.047 ± 0.11, p = 0.01), month 9 (0.141 ± 0.16 vs. 0.060 ± 0.12, p = 0.002) and month 12 (0.168 ± 0.20 vs. 0.077 ± 0.14, p = 0.004) were significantly smaller. No significant difference in severe adverse events was observed between the two groups. CONCLUSION: Orthokeratology effectively slowed axial elongation in children with low myopia. Specialty-designed ortho-k lenses with altered corneal reshaping characteristics demonstrated greater inhibition of axial elongation. TRIAL REGISTRATION: Chinese Clinical Trial Registry, ChiCTR2500113706, retrospectively registered on 2 December 2025.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparative effectiveness of orthokeratology versus highly aspherical lenslets in slowing myopia progression: a retrospective study.Eye and vision (London, England) · 2026
- Effects of orthokeratology lens wear on myopia progression and axial elongation in children: a 1:1 age-matched retrospective study.International journal of ophthalmology · 2026
- Similar annualized axial length elongation with 5.0-mm and 6.0-mm back optic zone diameter (BOZD) orthokeratology lenses in children and adolescents: a retrospective real-world analysis.Contact lens & anterior eye : the journal of the British Contact Lens Association · 2026
- Combined Small Treatment Zone Orthokeratology and Alternate-Day 0.01% Atropine for Axial Elongation Control in Rapidly Progressing Myopic Children.Translational vision science & technology · 2026
- Association between treatment zone characteristics and myopia control in monocularly myopic children wearing orthokeratology lensesScientific Reports · 2026
- Defocus incorporated multiple segment spectacle lenses versus orthokeratology lenses for myopia control: a non-inferiority randomised clinical trial.BMC ophthalmology · 2026