The Impact of Myopia Control Spectacle Lens Designs on Visual Function
Alfredo Desiato, Hiu Yan Lam, Reena Rani Anand, Inderjit Chatha, Nicola S. Logan, Amy L. Sheppard, James S. Wolffsohn, Deborah Laughton,
College of Optometrists · Applied Visions (United States)
Key points
From the paper's conclusion- To profile the immediate effect of defocus-modulating and contrast-modulating myopia control spectacle lens interventions on visual function.
Abstract
PURPOSE: To profile the immediate effect of defocus-modulating and contrast-modulating myopia control spectacle lens interventions on visual function. METHODS: Healthy myopic (mean spherical equivalent (MSE) -4.25 to -0.50 D) young adults, corrected with contact lenses, wore diffusion optics technology (DOT), defocus incorporated multiple segments (DIMS), highly aspherical lenslets (HAL) and standard single vision (SV) plano trial spectacle lenses, in a prospective, single-visit, double-blind, four-way randomised crossover study. Distance and near high- and low-contrast visual acuity (VA), contrast sensitivity, reading performance, accommodative facility, visual search task and accommodative accuracy were assessed foveally through the central zone (CZ) and/or peripheral zone (PZ) of the lenses. RESULTS: Twenty participants (16 female) were recruited, with a mean (±SD) age of 22.4 (±2.72) years and MSE -2.21 (±1.10) D. VAs through the PZ differed significantly between myopia control lenses and SV, with the HAL and DIMS exhibiting lower VA across all testing conditions (all p <0.05) and DOT demonstrating equivalence to SV with high contrast letters. Contrast sensitivity was similarly reduced for all lenses through the CZ, while HAL and DIMS performed worse than both SV and DOT through the PZ (p <0.01). Near acuity threshold, reading speed and critical print size through the PZ were comparable for SV, DOT and HAL (all p >0.05), whereas DIMS exhibited worse near acuity threshold and critical print size (p <0.001). No significant differences emerged for error score (p = 0.53), accommodative facility refocusing cycles (all p >0.05) or visual search duration (CZ: p = 0.68; PZ: p = 0.35). Accommodative response was similar across lenses (all p >0.05); however, SV had lower variability at distance through the PZ than DOT, HAL and DIMS (p <0.001). CONCLUSION: All three myopia control lenses exhibited visual performance comparable to standard SV lenses through the CZ. Clinicians should note differences in visual performance, especially VA and reading speed through the lens periphery and their relative testing.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effects of Myopia Control Spectacle Lenses on Peripheral Refraction and Contrast: Insights From Optical ModelingInvestigative Ophthalmology & Visual Science · 2026
- Association between contrast sensitivity and myopia control efficacy.BMC ophthalmology · 2026
- The Comparative Effectiveness of Four Myopia-Control Spectacle Lenses: A Real-World AIPW Cohort Study.Healthcare (Basel, Switzerland) · 2026
- Predicting the Efficacy of Myopia Control Spectacle Lenses by Simulating Their Optical Effect on the RetinabioRxiv · 2026
- Comparative longitudinal evaluation of DIMS, progressive addition and single-vision lenses on myopia progression, binocular and visual performance in Spanish children.PloS one · 2026
- Can Ocular Optical Biomarkers Predict Response to Contact-Lens Myopia Control? A Critical Review of Current Evidence.Diagnostics (Basel, Switzerland) · 2026