The effect of ventilation methods on liver movement during general anesthesia for thermal ablation of liver tumors
Karina Roheim Lappen, Ingrid Schrøder Hansen, Ida Björk, Daniel Østergaard, Per Steinar Halvorsen, Hilde Lang Orrem, Åsmund Avdem Fretland, Trygve Syversveen,
Key points
From the paper's conclusion- Results Standard ventilation resulted in the greatest movement with 5.8 mm of the left and 7.3 mm of the right inferior liver margin.
Abstract
Purpose Precise needle placement is vital for effective thermal ablation of liver tumors. Ventilation during anesthesia induces liver movement. This study compares different ventilation strategies and their impact on the movement of right and left inferior liver margins. Materials We conducted a non-randomized crossover study involving 20 patients scheduled for thermal ablation of liver metastases from colon cancer (November 2022–April 2024). Methods Five ventilation modes were evaluated: standard ventilation; low-tidal-volume, high-frequency ventilation; one-lung ventilation; and high-frequency jet ventilation with and without additional normal-frequency jet ventilation. Movement of the inferior liver margins was measured using ultrasound, recording cranio-caudal displacement of the left lobe at the midline and the right lobe at the anterior axillary line. Results Standard ventilation resulted in the greatest movement with 5.8 mm of the left and 7.3 mm of the right inferior liver margin. Low-tidal-volume, high-frequency ventilation reduced movement to 4.0 mm on the left and 4.6 mm on the right side. High-frequency jet ventilation caused the least movement, with 1.2 mm of the left and 0.5 mm of the right margin, the latter comparable to right-sided one-lung ventilation, which caused movement of the right margin of 1.6 mm. Conclusion Liver movement varied by ventilation method. High-frequency jet ventilation and right-sided one-lung ventilation provided the greatest stabilization, low-tidal-volume, high-frequency ventilation reduced movement compared with standard ventilation, and standard ventilation produced the largest movement. These differences may help guide the choice of ventilation strategy in procedures sensitive to organ motion. Trial registration Clinicaltrials.gov ID, NCT05129787 , registered 11/02/2021.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Efficacy and safety of intraoperative mechanical ventilation strategies during liver resection: a systematic review and meta-analysisAnesthesiology and Perioperative Science · 2026
- High-frequency low-tidal-volume ventilation reduces loop catheter displacement during pulsed field ablation for pulmonary vein isolationJournal of Anesthesia · 2026
- Needle Tract Ablation in Hepatic Interventions: Clinical Evidence for Hemostasis and Potential Tumor Seeding Risk ReductionCancers · 2026
- Analgesic strategies after hepatic resection: a network meta-analysis of randomized controlled trialsFrontiers in Surgery · 2026
- Autonomous Robotic Respiratory Motion Compensation and Needle Insertion via MRI Correspondence Models for CT‐Guided Hepatic Percutaneous ProceduresThe International Journal of Medical Robotics and Computer Assisted Surgery · 2026
- Thermal ablation in posterosuperior liver segments: Is this an indication to laparoscopic approach?Annals of Hepato-Biliary-Pancreatic Surgery · 2026