Systematic review of spalling fire resistance and residual capacity in advanced and composite concrete columns exposed to fire
Wael Rami Almakinachi, Ali Ihsan Salahaldin, Diyaree Jalal Ghaidan, Junaid K. Ahmed
Key points
From the paper's conclusion- The results show that the addition of 0.9–2.0 kg/m 3 polypropylene fibers decreases the explosive spalling in HSC during the ISO 834 fire.
Abstract
Advanced concrete systems such as HSC, UHPC, RPC, CFST and SRC columns are used in high-rise construction due to their strength, durability and structural efficiency. Their performance is still influenced by explosive spalling, serious degradation of mechanical properties and large reductions in residual load-bearing capacity after fire. The existing fire design rules calibrated for normal strength concrete do not yet integrate the complex thermal and mechanical deterioration mechanisms of advanced concrete systems. Systematic reviews following PRISMA guidelines This PRISMA-guided systematic review addresses this gap. The results show that the addition of 0.9–2.0 kg/m 3 polypropylene fibers decreases the explosive spalling in HSC during the ISO 834 fire. However, their performance in UHPC depends on the mixture composition, moisture content, and heating rate and needs to be evaluated for each formulation. The maximum damage to CFST columns with axial load ratios of 0.3–0.5 and fire resistance ratings of 30 to 90 min was caused by eccentric loading and high slenderness ratios. The residual axial load capacity of UHPC columns after fire was 0.35–0.78 of the initial capacity depending on the axial load ratio, cross-sectional dimensions and fiber dose. The axial strains after fire were 2.3% for CFST columns and 0.5–0.8% for exposed HSC and UHPC columns. Columns exposed to fire in high-rise structural frames may shrink more than columns not exposed to fire. This is the first cross-typology synthesis to clearly distinguish the during-fire resistance from the post-fire residual capacity and to benchmark the data against Eurocode 2, Eurocode 4 and ACI 216.1.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Post-fire residual structural capacity of cement- and geopolymer-based UHPC columnsConstruction and Building Materials · 2026
- Fire Resistance of Steel-Reinforced Concrete Columns: A Review of Ordinary Concrete to Ultra-High Performance ConcreteBuildings · 2025
- Compression behavior of steel‐ PVA high‐strength self‐compacting concrete short column exposed to elevated temperaturesStructural Concrete · 2026
- Comparative Thermal Performance of Ultra-High-Performance Concrete and Geopolymer Concrete: Influence of Steel Fibre Geometry on Residual Mechanical and Chemical Properties.Materials (Basel, Switzerland) · 2026
- Residual Flexural Behaviour of Reinforced Self-Compacting Concrete Beams After Fire Exposure: Effects of Fine-to-Coarse Aggregate Ratio, Heating Rate, and Boundary RestraintConstruction Materials · 2026
- An Experimental Study on the Analysis of Factors Influencing Explosive Spalling of Concrete Under FireFire · 2026