Development of a rotating microfluidic device for efficient solid-phase extraction in food analysis.
Masaya Shuto, Takahiro Matsuda, Tsukasa Endo, Kazuhiro Kobayashi, Toshihiro Kasama, Madoka Takai, Ryo Miyake
Global Food Safety Institute, Nissin Foods Holdings Co., Ltd, 2100 Tobuki- machi, Hachioji, Tokyo, 192-0001, Japan. masaya.shuto@nissin.com. · Global Food Safety Institute, Nissin Foods Holdings Co., Ltd, 2100 Tobuki- machi, Hachioji, Tokyo, 192-0001, Japan.
Key points
From the paper's conclusion- Thus, this device is expected to contribute to labor and space savings as well as reduced environmental impact in food analysis pretreatment.
Abstract
In recent years, microchemical devices have garnered increasing attention for enabling highly efficient chemical processes using minute sample volumes while offering advantages such as compactness and low environmental impact. In this study, a rotating microfluidic device capable of processing sample volumes on the order of several hundred microliters was developed utilizing centrifugal force as the driving mechanism. The device was designed to streamline labor-intensive solid-phase extraction (SPE) procedures commonly used in food analysis pretreatment. A centrifugal microfluidic device featuring a conditioning unit for SPE column preparation and a pretreatment unit for sample processing was developed. A validation study was conducted using this device on vitamin B1 (thiamine) retained on an SPE column. The measurement results met the relevant guidelines, and the method employing this device reduced processing time compared to conventional methods. As a preliminary evaluation, ascorbic acid 2-glucoside was also tested as a flow-through-mode analyte. However, device-associated chromatographic interference precluded confirmation of the quantitative validity of the method. Thus, this device is expected to contribute to labor and space savings as well as reduced environmental impact in food analysis pretreatment. However, further device design improvements and additional validation are required to expand its range of applicable targets.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Microfluidic pretreatment devices for milk safety at the point of care.Mikrochimica acta · 2026
- A universally automated and ultra-efficient pretreatment device for rapid assay of mycotoxins in grain and oil.Food chemistry · 2026
- Centrifugal mini-SPE cleanup for monitoring contaminants in food. Part I: Comparison with dispersive-SPE.Journal of chromatography. A · 2026
- Microscale solid-phase extraction: advances in sorbent formats, system design, integration, and detection methods.Analytical and bioanalytical chemistry · 2026
- A microfluidic paper-based distance-readout immunosensor for visual quantification of Salmonella typhimurium.Biosensors & bioelectronics · 2026
- Thin film solid-phase microextraction as a high-capacity format for volatile organic compound profiling of novel protein sources: A multi-device comparison by gas chromatography mass spectrometry.Food chemistry · 2026