A method for determining moment values of elution peaks measured by means of high-performance liquid chromatography or capillary electrophoresis.
Kanji Miyabe, Aki Yoshikawa
Department of Chemistry, Faculty of Science, Rikkyo University, 3-34-1, Nishi-Ikebukuro, Toshima-ku, Tokyo, 171-8501, Japan. kmiyabe@rikkyo.ac.jp. · Department of Chemistry, Faculty of Science, Rikkyo University, 3-34-1, Nishi-Ikebukuro, Toshima-ku, Tokyo, 171-8501, Japan.
Key points
From the paper's conclusion- Moment analysis of first absolute (µ1A) and second central (µ2C) moments of elution peaks measured by using high-performance liquid chromatography or capillary electrophoresis is effective for extracting the information about chemical phenomena relating to their separation behavior from equilibrium and kinetic points of view.
Abstract
Moment analysis of first absolute (µ1A) and second central (µ2C) moments of elution peaks measured by using high-performance liquid chromatography or capillary electrophoresis is effective for extracting the information about chemical phenomena relating to their separation behavior from equilibrium and kinetic points of view. It is known that elution peak profiles should be integrated to obtain more accurate values of µ1A and µ2C. This means that it is required to appropriately determine the range for integrating the elution peak profiles. Our research group has used a method for determining the start and end points of the integration range. However, it seems that signal noise, baseline drift, and peak asymmetry affects the selection of the integration range and the accuracy in the determination of µ1A and µ2C values of elution peaks. Simulated elution peaks were prepared by adding signal noise of different intensities to a base Gaussian peak and by changing the slope of baseline. Asymmetrical peaks, i.e., tailing and leading, were also prepared by using the Exponentially Modified Gaussian function while changing the degree of asymmetry. The method was applied to choose the start and end points for integrating the simulated elution peaks. Then, the values of µ1A and µ2C were calculated by integrating the simulated elution peak profiles in the integration range. It was tried to clarify how the magnitude of signal noise, baseline drift, and peak asymmetry affect the selection of the integration range of elution peaks and the determination of their µ1A and µ2C values.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Accuracy of methods for integrating overlapping chromatographic peaks: A systematic evaluation.Journal of chromatography. A · 2026
- Peak integration errors and analyst interaction in pharmaceutical quality control using LC-UV.Journal of pharmaceutical and biomedical analysis · 2026
- Molecular diffusion of oligonucleotides: Influence of temperature, ion-pairing reagents, and chemical modifications under relevant chromatographic conditions.Journal of chromatography. A · 2026
- General-Purpose Algorithm for Baseline Correction Based on Inscribed PolynomialsAnalytical Chemistry · 2026
- A modeling framework for uncertainty quantification in filter-plate-based high-throughput screening of the chromatography partition coefficient.Journal of chromatography. A · 2026
- Analytical Solution and Temporal Moments of the Tempered Prabhakar Fractional General Rate Model for Linear Liquid Chromatography.Analytical chemistry · 2026