International Journal of Computational Intelligence Systems

An Explainable Depthwise Separable-Fire Convolutional Model for Resource-Constrained Diagnosis of Cardiac Rhythm

Abdullah Al-Mamun Bulbul, Moid Sandhu, Md Abdul Awal, Saad Aloteibi, Mohammad Ali Moni

Key points

From the paper's conclusion
  • Overall, the results indicate that efficient multi-class beat-type classification is feasible on resource-constrained devices.

Abstract

Cardiac rhythm monitoring requires high accuracy, speed, and energy efficiency to enable continuous use in wearable and bedside monitoring devices. In this study, we perform fine-grained classification of 16 MIT-BIH beat annotation categories. We propose LEDSNet, a lightweight one-dimensional convolutional network that achieves 98.58% accuracy and 98.57% F1-score, with no classes left undetected, on the MITBIH Arrhythmia dataset under a segment-wise evaluation protocol. Patient-wise splitting was not feasible for the full 16-class setting because several rare beat types occur in only a single patient/record. Therefore, to additionally assess patient-independent generalization, we performed a complementary patient-wise evaluation using a 5-class AAMI mapping, where LEDSNet achieved 92.90% accuracy, 92.75% precision, 92.90% recall, and 92.40% F1-score. To address the heavy class imbalance in the arrhythmia dataset, we used a class-conditional Wasserstein GAN with a gradient penalty for data augmentation, which outperformed SMOTE. A systematic five-stage ablation study validated the optimal architecture and hyperparameters. A 10-fold stratified training-validation stability analysis, in which models from different training-validation folds were evaluated on the same fixed hold-out test set, demonstrated stable performance under the same segment-wise protocol with a mean accuracy of 98.51% ± 0.07%. The model requires only 0.11 MB of memory and $$1.4\times 10^5$$ FLOPs, reducing training energy consumption and estimated $$\text {CO}_{2eq}$$ emissions by at least 37.78% compared with previous lightweight models. For deployment evidence, inference on a Raspberry Pi 4 Model B classified 31,713 pre-segmented beats in just 3.58 s (about 8,855 segments/s). Besides, LIME-based analysis suggests the model focuses on clinically meaningful waveform regions. Overall, the results indicate that efficient multi-class beat-type classification is feasible on resource-constrained devices.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

An Explainable Depthwise Separable-Fire Convolutional Model for Resource-Constrained Diagnosis of Cardiac Rhythm — Science Skim