Advances in Metallic Fixation Materials for Bone Fracture Fixation: A Review
S-Sina Mohammadi, Sunjeev S. Phull, Darya Pirmohammadi, Ali Adli, Sara Mazinanian, Mark R. Towler
Key points
From the paper's conclusion- Future development should prioritize synchronization of mechanical retention and degradation with bone healing, together with standardized long-term in vivo evaluation of corrosion products, biological responses, and fixation performance.
Abstract
Metallic biomaterials remain central to bone fracture fixation because they provide the mechanical stability required to maintain alignment and support healing under physiological loading. This review examines conventional surgical metals, including stainless steel (SS), cobalt–chromium (Co–Cr) alloys, and titanium (Ti) and its alloys, together with emerging resorbable metals based on magnesium (Mg), iron (Fe), and zinc (Zn). SS remains widely used because of its strength, low cost, and established clinical history, although its high elastic modulus, corrosion-related ion release, limited osseointegration, and susceptibility to infection are limitations. Co–Cr alloys provide superior strength, hardness, wear resistance, and corrosion resistance, but their high stiffness and potential release of Co and Cr species restrict fracture-fixation applications. Ti alloys offer a favorable combination of low density, corrosion resistance, biocompatibility, and a lower elastic modulus than SS and Co–Cr, although stress shielding, implant-associated infection, and concerns regarding alloying-element release persist. Resorbable Mg-, Fe-, and Zn-based systems seek to provide temporary mechanical support while gradually transferring load to regenerating bone thus eliminating implant-removal surgery. However, rapid Mg degradation, slow Fe resorption, and the limited intrinsic strength of Zn remain barriers to clinical translation. Alloying, controlled porosity, additive manufacturing, thermomechanical processing, and surface modification can improve mechanical, degradation, osseointegration, and antibacterial performance, but may introduce concerns involving fatigue resistance, localized corrosion, ion release, manufacturing complexity, and long-term safety. Future development should prioritize synchronization of mechanical retention and degradation with bone healing, together with standardized long-term in vivo evaluation of corrosion products, biological responses, and fixation performance.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Biodegradable Metals and Corrosion Control: Challenges, Limits and New Opportunities for Innovating in Orthopedic FixationsMaterials · 2026
- Research Progress on Biodegradable Porous Metallic Bone ImplantsACS Applied Energy Materials · 2026
- Mechanical Properties and Corrosion Behavior of Biodegradable Metals: Current Challenges.Materials (Basel, Switzerland) · 2026
- Progress and Current Status of Biodegradable Metallic Implants: Mini-ReviewCorrosion and Materials Degradation · 2026
- Design and theoretical assessment of Ti-Mo-Nb-Sn alloys for biomedical applications: a review.Frontiers in bioengineering and biotechnology · 2026
- Emerging bone adhesives for early fixation and enhanced healing of fracturesMaterials & Design · 2026