Discover Artificial Intelligence

Reliable methane storage screening and inverse design of metal organic frameworks under distribution shift

Safiul Haque Chowdhury, Rakib Ahammed Diptho, Pial Ghosh

Computational

Key points

From the paper's conclusion
  • We study the methane deliverable (working) capacity across a public database of 252,353 frameworks described by 14 geometric and 148 chemical descriptors, with uptake from grand canonical Monte Carlo simulation at 5.8 and 65 bar.

Abstract

Adsorbed natural gas storage in metal-organic frameworks (MOFs) is a leading route to energy-dense methane storage, but the design space is too large for exhaustive simulation. We study the methane deliverable (working) capacity across a public database of 252,353 frameworks described by 14 geometric and 148 chemical descriptors, with uptake from grand canonical Monte Carlo simulation at 5.8 and 65 bar. The database is 97.58% computationally enumerated and 2.42% derived from experimentally reported crystal structures, a composition that shapes every result. A gradient boosting regressor reaches $$R^{2}=0.9963$$ (MAE 0.329 mmol/g) under a random split. Accuracy degrades only modestly under eight structure-aware protocols (topology-grouped $$R^{2}=0.9877$$ ), but training on enumerated frameworks and testing on experimental ones reduces the Spearman correlation from 0.998 to 0.879. Ablation shows 14 geometric descriptors alone recover $$R^{2}=0.9903$$ under a grouped split, so the chemical descriptors buy mainly ranking quality. Split-conformal intervals attain nominal marginal coverage (90.1 and 95.1%) but only 74.7% in the top capacity percentile, and 54.8−87.3% when a whole library is held out. Mondrian and shift-weighted variants restore near-nominal coverage within a fixed split. Reporting all three engineering units together, no framework meets the 263 cm 3 (STP) cm −3 volumetric target, while 1405 (0.56%) exceed 0.5 g g −1 . Benchmarked against direct screening, descriptor-space optimisation falls short: ranking recovers the 57.9 mmol/g record holder in a top-ten shortlist, whereas optimise-then-retrieve returns 17.7−28.8 mmol/g and none of the true top ten. Candidates are database-enumerated; no experimental validation is reported.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Reliable methane storage screening and inverse design of metal organic frameworks under distribution shift — Science Skim