Measurements of erythema effective ultraviolet irradiance in artificial tanning devices in Switzerland.
Yannik Waeber, Fabio Rinderer, Florian Stuker, Martin Meier, Evelyn Stempfel
Federal Office of Public Health, Bern, Switzerland. yannik.waeber@bag.admin.ch. · Federal Institute of Metrology METAS, Bern-Wabern, Switzerland.
Key points
From the paper's conclusion- Overall, 1'521 individual measurements were performed on 436 artificial tanning devices across Switzerland.
Abstract
Artificial tanning devices expose users to ultraviolet radiation and are associated with an increased risk of skin cancer. To protect users, Swiss legislation, among other requirements based on the SN EN 60335-2-27, limits the total erythema effective irradiance of artificial tanning devices to. Additionally, only UV-Type 3 devices may be used in unsupervised settings. From 2022 to 2024, Swiss cantonal authorities conducted a nationwide measurement campaign to assess compliance with the limits. For this, a portable measurement system, based on a stray-light-suppressing array spectroradiometer was developed and evaluated against precision double-monochromator measurements. The developed system achieved comparable accuracy while enabling rapid in-situ conformity assessments. Overall, 1'521 individual measurements were performed on 436 artificial tanning devices across Switzerland. While of the measured devices complied with the legal limit for the total erythema effective irradiance, only met the criteria of UV-Type 3 devices. After corrective actions on previously non-compliant devices, follow-up measurements showed that of all tested devices were compliant. The results demonstrate the suitability of the developed measurement system and reveal substantial compliance deficiencies, highlighting the need for continued inspection of artificial tanning devices.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Cost–benefit analysis of far-UVC lamps for reducing indoor infection transmission in Switzerland and Germany: Insights from the CERN Airborne Model for Indoor Risk Assessment (CAiMIRA)Global Health Economics and Sustainability · 2026
- UV Imaging-Based Method for Quantifying Sunscreen Application and PersistenceCosmetics · 2026
- Evaluating tools for predicting and measuring radiometric performance of germicidal ultraviolet systemsPhotochemistry and Photobiology · 2026
- Spectral irradiance and power responsivity calibrations from 200 nm to 400 nm using the new NIST Ultraviolet Spectral Comparator FacilityMetrologia · 2026
- Radiometrically Equivalent Comparison of 254 nm Low-Pressure Mercury Lamps and InGaN 280 nm UV-C LEDs for Surface Disinfection.ACS omega · 2026
- Evidence Appraisal and Engineering Translation of Ultraviolet Control for Crop Diseases: A Systematic ReviewAgriculture · 2026