Indian journal of orthopaedics

Pack-Size-Dependent Effects of Bone Cement Use in Unicompartmental Knee Arthroplasty: A Prospective Randomized Trial.

Zhenbao Lu, Qingshan Xu, Yuhua Feng, Yebao Xu, Xu Wang, Qijin Wang

Department of Orthopaedics, Affiliated Mindong Hospital, Fujian Medical University, No. 89 Heshan Road, Fu'an, 355000 Fujian China.

Randomised

Key points

From the paper's conclusion
  • In UKA without substantial bone defects, a 20-g cement allocation strategy reduces cement waste while maintaining comparable short-term radiographic fixation and clinical outcomes to a 40-g strategy. Under institutional pricing assumptions, smaller packs were associated with estimated cement acquisition cost savings, so 20-g allocation may be considered in routine UKA when substantial defects are absent.

Abstract

PURPOSE: Excess bone cement is often discarded in unicompartmental knee arthroplasty (UKA), increasing costs and potentially cement-related complications. Although cement inefficiency is recognized in total knee arthroplasty (TKA), no prospective randomized trial has assessed the effect of cement pack size in UKA. We compared 20-g and 40-g cement packs for cement utilization, radiographic fixation, and 1-year outcomes. METHODS: In this prospective single-center randomized trial (from September 1, 2022 to June 30, 2024), patients undergoing medial UKA were allocated to 40-g (n = 98) or 20-g (n = 100) cement packs. Outcomes included cement used, wastage rate, penetration depth, radiolucent lines, extrusion, and 1-year implant survival. Groups were compared using appropriate parametric or nonparametric tests, and survival was analyzed using the Kaplan-Meier method with the log-rank test. RESULTS: Cement used was similar (≈8.1 g; P = 0.173), but the 40-g group had a higher wastage rate than the 20-g group (85.76% vs. 71.49%; P < 0.001). Cement penetration (≈1.5 mm femur, ≈2.5 mm tibia), radiolucent lines (≈18-20%), and extrusion (≈12-18%) were comparable. One patient in the 40-g group developed infection requiring debridement, antibiotics, and implant retention (DAIR). One-year implant survival was 100% in the 20-g group and 99.0% in the 40-g group (P > 0.3). CONCLUSIONS: In UKA without substantial bone defects, a 20-g cement allocation strategy reduces cement waste while maintaining comparable short-term radiographic fixation and clinical outcomes to a 40-g strategy. Under institutional pricing assumptions, smaller packs were associated with estimated cement acquisition cost savings, so 20-g allocation may be considered in routine UKA when substantial defects are absent.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers