Disc angle, screw distance, and disc flip as radiographic indicators of tether breakage after thoracolumbar VBT.
Ahmad Jurban, Ahmad Essa, Mahmoud Alkharsawi, Christopher D Witiw, Per D Trobisch
Department of Spine Surgery, Eifelklinik St. Brigida, Simmerath, Germany. · Division of Orthopedics, Department of Surgery, Shamir Medical Center (Assaf Harofeh), Zerifin, Israel. jurbanja0@gmail.com.
Key points
From the paper's conclusion- In this exploratory diagnostic study, delta disc angle, delta screw distance, and disc flip showed promising apparent diagnostic performance for detecting tether failure after VBT in this revision cohort. The proposed composite score offers a potentially useful multi-parametric approach to identifying tether breakage. Nevertheless, the thresholds and score remain preliminary and require independent validation in a larger, representative VBT population before clinical application.
Abstract
PURPOSE: To evaluate the diagnostic performance of radiographic parameters for detecting tether breakage using intraoperatively confirmed tether failure as the reference standard. METHODS: This radiographic exploratory diagnostic study included consecutive patients with adolescent idiopathic scoliosis who underwent thoracolumbar vertebral body tethering (VBT) and subsequently required revision surgery for tether breakage. Standing whole-spine radiographs obtained at the first postoperative erect time point and follow-up were analyzed. Segment-level measurements included inter-screw distance, inter-screw angle, disc angle, screw flip, and disc flip. Tether breakage was confirmed intraoperatively during revision surgery. Diagnostic performance was assessed for each parameter. A composite breakage score was developed using the strongest predictors. RESULTS: Thirteen patients with 65 analyzed segments were included; 44 segments had intraoperatively confirmed tether breakage. Delta disc angle showed the highest diagnostic performance, with an optimal cutoff of 2.9° yielding 89.0% sensitivity, 86.0% specificity, and an area under the curve (AUC) of 0.92. Delta screw distance also demonstrated strong accuracy, with a cutoff of 7.4% yielding 86.0% sensitivity, 90.0% specificity, and an AUC of 0.89. Disc flip showed high diagnostic performance among binary predictors, with 93% sensitivity, 86% specificity, and an AUC of 0.89. The composite breakage score demonstrated increasing breakage rates from 6.7% for a score of 0 to 100.0% for a score of 3. CONCLUSION: In this exploratory diagnostic study, delta disc angle, delta screw distance, and disc flip showed promising apparent diagnostic performance for detecting tether failure after VBT in this revision cohort. The proposed composite score offers a potentially useful multi-parametric approach to identifying tether breakage. Nevertheless, the thresholds and score remain preliminary and require independent validation in a larger, representative VBT population before clinical application.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Reoperation and fusion after documented tether breakage following vertebral body tethering: a systematic review and meta-analysis.Spine deformity · 2026
- Tether Breakage after Vertebral Body Tethering: A Systematic Review and Meta-Analysis of Time-dependent Risk and Clinical Consequences.Global spine journal · 2026
- Vertebral body tethering: a state-of-the-art review.Spine deformity · 2026
- Redefining Success and Characterizing Midterm Growth Modulation: Analysis of Radiographic Outcomes in 2 Years Following Vertebral Body Tethering.JB & JS open access · 2026
- Who are the best candidates? Factors predicting success and failure of vertebral body tethering.Spine deformity · 2026
- When is Vertebral Body Tethering in a Patient With an Open Triradiate Cartilage a Good Idea?Journal of pediatric orthopedics · 2026