Development of in vitro skin corrosion test using KeraSkin™.
Jeong-Hyun Hong, Jungeun Park, Jee-Hyun Hwang, Eun-Ji Gwak, Su-Hyon Lee, Kyung-Min Lim
College of Pharmacy, Ewha Womans University, Seoul, 03760 Republic of Korea. · GLP Center, Biosolution Co., Ltd., Seoul, 06746 Republic of Korea.
Key points
From the paper's conclusion- Collectively, we demonstrated that KeraSkin™ can be a reliable in vitro model for skin corrosion test, expanding the availability of validated non-animal methods for global chemical safety assessment.
Abstract
Skin corrosion and irritation are critical local toxicological endpoints associated with chemical exposure. OECD has approved the use of the Reconstructed Human Epidermis (RhE) model, KeraSkin™, as me-too in vitro skin irritation test of OECD Test Guideline (TG) 439. Here, we explored the applicability of KeraSkin™ as a me-too test method for in vitro skin corrosion test OECD TG 431, to expand its validated use beyond skin irritation test. Thirty reference chemicals, including Category 1A, 1B/1C, and non-corrosive substances as described in OECD TG 431 performance standards (PS), were tested. Test chemicals were applied for 3 or 60 min, and cell viability (CV) was measured using MTT assay. Classification criteria were based on viability thresholds, wherein <15% at 3 min indicates Category 1A corrosives, ≥15% at 3 min and <15% at 60 min, Category 1B/1C, and ≥50% at 3 min and ≥15% at 60 min indicates non-corrosives. The KeraSkin™ skin corrosion test demonstrated reliable predictive capacity with 100% sensitivity, 70% specificity, 90% accuracy (corrosive/non-corrosive), and 76.7% sub-category accuracy in the predictive capacity assessment using 30 chemicals, which satisfies the accuracy criteria of OECD TG 431 PS. Collectively, we demonstrated that KeraSkin™ can be a reliable in vitro model for skin corrosion test, expanding the availability of validated non-animal methods for global chemical safety assessment. Further full validation test is underway for the approval of the KeraSkin™ skin corrosion test for a me-too test method of OECD TG 431.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Stepwise Skin Irritation Assessment Approach Integrating in Vitro Skin Irritation Testing and Human Patch Testing.Journal of applied toxicology : JAT · 2026
- Replacing HaCaT keratinocytes with 3D reconstructed human epidermis in a THP-1 coculture dendritic cell activation assay: quantitative skin sensitization potency assessment and structure-potency relationships.NAM journal · 2026
- Assessing the Skin Sensitizing Potential of Constituents and Leachables from Wearable Devices Using GARDskin and Associated Applications.Toxics · 2026
- Current and emerging new approach & methodologies for skin hazard assessmentToxicological Research · 2026
- In Vitro 3D Human Airway and Skin Models for Assessing the Cytotoxicity of Ethanol Mist Used in Cultural Heritage DecontaminationApplied Sciences · 2026
- Optimizing skin sensitization prediction across activity cliffs: a comparative analysis of K-nearest neighbours vs random Forest.Frontiers in toxicology · 2026