Enhancing the accuracy of bioimpedance-derived appendicular skeletal muscle mass in aged adults through machine learning.
Bruno Micael Zanforlini, Nicolò Biasetton, Alessandro Perencin, Giorgia Longo, Elena Barzizza, Chiara Curreri, Anna Bertocco, Chiara Ceolin,
Department of Medicine (DIMED), University of Padua, Via Giustiniani 2, 35128, Padua, Italy. brunomicael.zanforlini@unipd.it. · Department of Management and Engineering, University of Padova, Stradella San Nicola 3, 36100, Vicenza, Italy.
Key points
From the paper's conclusion- Integrating ML into BIA-based muscle assessment enables clinicians to quantify the reliability of individual ASMM estimates, even in patients with comorbidities. This approach provides a standardized framework for accepting or rejecting bedside estimations, enhancing clinical decision-making.
Abstract
PURPOSE: Appendicular Skeletal Muscle Mass (ASMM) estimation via Bioelectrical Impedance Analysis (BIA) is a high-quality and bedside-accessible method. However, its accuracy is limited in comorbid populations, and determining the degree of error at the bedside remains a challenge. This study evaluates the application of Machine Learning (ML) algorithms as a decision-support layer to identify patients for whom the BIA-derived ASMM value is accurate. METHODS: This cross-sectional study included 701 participants aged ≥65 years (550 healthy subjects, 151 outpatients). ASMM measured by Dual-Energy X-ray Absorptiometry served as the reference. An absolute error ≤1.14 kg (the original equation's standard error) defined accurate estimation. Five algorithms-Extreme Gradient Boosting, Support Vector Machine (SVM), Random Forest, Logistic regression, and Neural Networks-were trained using three hierarchical sets of predictors: (1) anthropometric and bioimpedance variables, (2) model 1 plus handgrip strength, and (3) model 2 plus anthropometric circumferences (arm, waist, and calf) and knee height. RESULTS: Estimation error was minimal in healthy subjects but markedly higher in outpatients (median absolute difference 0.81 vs. 2.37 kg, p<0.001). Accurate estimates dropped from 62.4% in healthy individuals to 25.2% in outpatients. Discriminative performance improved progressively with each predictor set. In Set 3, SVM achieved the highest cross-validation Area Under the Curve (0.813) and a test AUC of 0.867, with an accuracy of 0.70. CONCLUSIONS: Integrating ML into BIA-based muscle assessment enables clinicians to quantify the reliability of individual ASMM estimates, even in patients with comorbidities. This approach provides a standardized framework for accepting or rejecting bedside estimations, enhancing clinical decision-making.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Toward Clinically Feasible Assessment of Muscle Mass: Validation of a Seated Bioelectrical Impedance Device Against Dual-Energy X-Ray Absorptiometry (DXA) in Older Adults.Sensors (Basel, Switzerland) · 2026
- Population-based appendicular skeletal muscle mass equation: Weak association between predicted and bioimpedance-derived changes during stroke and hip-fracture rehabilitation.Archives of gerontology and geriatrics · 2026
- Interpretable bioimpedance-based modeling of body composition and metabolic indices related to physical function in maintenance hemodialysis patients.Frontiers in nutrition · 2026
- Validity and agreement of bioelectrical impedance equations against dual energy X-ray absorptiometry for muscle mass assessment in patients on hemodialysis: A cross-sectional study.Nutrition in clinical practice : official publication of the American Society for Parenteral and Enteral Nutrition · 2026
- Equation-dependent anthropometric muscle-mass estimates and functional screening limitations in home-bound older adults.Clinical nutrition ESPEN · 2026
- An appropriate ASMI cutoff value enhances utilization of the CHARLS database for studying sarcopeniaThe Journals of Gerontology Series A · 2026