Design and additive manufacturing by FDM, feasibility and reproducibility of a anthropomorphic-heterogeneous silicone/TPU/ABS mannequin for CT image analysis: a proof-of-concept study
Rebeca Franco-Reyes, Eduardo Moreno-Barbosa, Alonso Antonio Collantes-Gutiérrez, Benito Celis-Alonso, Fernando Moreno-Barbosa, Marco A. Morales, Ricardo Agustín-Serrano
Key points
From the paper's conclusion- These results demonstrate the potential of FDM technology as an accessible alternative for manufacturing anatomical mannequins used in research and medical simulation applications.
Abstract
Anthropomorphic mannequins are widely used in biomedical research, medical imaging studies, and clinical training. However, commercial models are often expensive and have limitations in terms of anatomical customization. This study evaluates the feasibility and reproducibility of manufacturing a heterogeneous anthropomorphic mannequin using various polymeric materials via additive manufacturing with fused deposition modeling (FDM) technology. The size and shape are based on specific biometric measurements to emulate clinical situations. The mannequin is designed in three layers, and different 3D printing materials were selected for each tissue: silicone ink (skin), thermoplastic polyurethane (TPU, muscle), and acrylonitrile butadiene styrene (ABS, cortical and trabecular tissue). The novel aspect of this mannequin is the design of the trabecular structure, obtained from a mathematical model. Furthermore, a novel manufacturing methodology for the heterogeneous anthropomorphic structure of skeletal mannequins is presented. Morphological characterization from computed tomography (CT) images was used to evaluate the FDM manufacturing process and the resulting internal structures. Quantitative and qualitative analyses, including fractal dimension analysis and Hounsfield Unit (HU) measurements, were performed to assess the consistency of geometric complexity and the radiological response of the selected materials. The statistical analysis using a linear mixed-effects model (LMM) evaluated differences in fractal dimension among independently manufactured phantoms while accounting for the correlation among tomographic slices obtained from the same phantom. HU measurements provided a quantitative comparison between the selected materials and the corresponding human tissues. These results demonstrate the potential of FDM technology as an accessible alternative for manufacturing anatomical mannequins used in research and medical simulation applications.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Nonlinear Hyperelastic Characterization of the PolyJet Digital Anatomy Material Library and Selection Methodology for Tissue-Mimicking Anatomical Models.Journal of biomedical materials research. Part B, Applied biomaterials · 2026
- Investigation of the most suitable 3D printing method and tissue equivalent materials for mimicking glandular-adipose tissues for production of breast phantom.Physical and engineering sciences in medicine · 2026
- Beyond FDM and SLA: Extending a Polymer Additive Manufacturing Benchmark with Silicone Direct Ink Writing for Flexible and Biocompatible ApplicationsMaterials · 2026
- Investigation on Mechanical Properties of Functional Graded Hybrid TPMS Structures Inspired Bone ScaffoldsPolymers · 2026
- Manufacturable design and experimental investigation of functionally graded TPMS-based root analogue implant for dental applicationsResults in Engineering · 2026
- Functionally Graded Polymer Lattice Structures Enabled by Multi-Material Fused Deposition Modeling: Current Progress, Challenges, and Future Perspectives.Polymers · 2026