Nano-micro letters

Aligning Out-of-Plane Polarization in 2D Ferroelectric Perovskite Wafer Boosts Interlayer Carrier Transport for Efficient X-Ray Detection.

Chenhao Deng, Shihai You, Haiqing Zhong, Xiankan Zeng, Xiaolong Hao, Jiasheng Xie, Zheng Zhou, Zhangjian Jin,

Key Laboratory of Advanced Technologies of Materials (Ministry of Education), School of Materials Science and Engineering, Research Institute of Frontier Science, Southwest Jiaotong University, Chengdu, 610031, People's Republic of China. · Key Laboratory of Advanced Technologies of Materials (Ministry of Education), School of Materials Science and Engineering, Research Institute of Frontier Science, Southwest Jiaotong University, Chengdu, 610031, People's Republic of China. shihai.you@swjtu.edu.cn.

Key points

From the paper's conclusion
  • This work demonstrates that aligning the intrinsic ferroelectric polarization in polycrystalline wafers is a viable strategy to enhance vertical carrier transport, paving the way toward high-performance, flat-panel X-ray detectors based on 2D MHPs.

Abstract

2D metal halide perovskites (MHPs) featuring suppressed ion migration and enhanced structural stability are highly promising for direct X-ray detection but suffer from poor interlayer carrier transport and difficulty in scaling single crystals. Here, we overcome these limitations by fabricating high-quality, centimeter-sized polycrystalline wafers of a 2D ferroelectric MHP with out-of-plane spontaneous polarization, (Mpda)PbBr4 (Mpda = N-methyl-1,3-propanediamine), via a facile hot-pressing strategy. This process induces a horizontal orientation of microcrystals, resulting in vertical alignment of their polar axes and thus macroscopic polarization in the wafer. Such an intriguing polarization generates a switchable built-in electric field that can promote separation and interlayer transport of photogenerated carriers, exhibiting a bulk photovoltage of up to 2 V. Consequently, the vertical X-ray detector can not only be operated in self-powered mode but also achieve a high sensitivity of 2285 μC Gy-1 cm-2 and an ultralow detection limit of 7.2 nGy s-1 under a small bias (16 V). The device also exhibits remarkable operational stability and high-resolution X-ray imaging capability. This work demonstrates that aligning the intrinsic ferroelectric polarization in polycrystalline wafers is a viable strategy to enhance vertical carrier transport, paving the way toward high-performance, flat-panel X-ray detectors based on 2D MHPs.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers