Ophthalmology and therapy

Scleral Allograft-Reinforced Cyclodialysis Combined with Phacoemulsification or Performed as a Standalone Procedure: 24-Month Outcomes from the Multicenter CREST Study.

Robert N Weinreb, Lorraine Provencher, Alex S Huang, Arkadiy Yadgarov, Matthew Rouse, Brian Francis, Tsontcho Ianchulev, Robert Chang

Shiley Eye Institute, University of California San Diego, La Jolla, CA, USA. · Vance Thompson Vision, Omaha, NE, USA.

Trial · n=176

Key points

From the paper's conclusion
  • Allograft-reinforced cyclodialysis effectively lowered IOP and medication use through 24 months.

Abstract

INTRODUCTION: Acellular scleral allograft-reinforced cyclodialysis is a bio-interventional surgery (BIOS) to lower intraocular pressure (IOP). We report 2-year efficacy and safety outcomes when the procedure is performed in combination with phacoemulsification and as a standalone procedure in eyes with open-angle glaucoma. METHODS: Analysis of the multicenter CREST real-world evidence study of eyes undergoing allograft-reinforced cyclodialysis with AlloFlo™ Uveo (Iantrek, Inc., White Plains, NY; NCT05506423). Eyes attending the month-24 visit were analyzed: 176 eyes undergoing phaco-combined surgery (cohort 1) and 32 standalone eyes (cohort 2). Values recorded after secondary procedures were censored. Cohort 1 only was stratified by low, moderate, or high baseline IOP (≤ 15, 16-20, ≥ 21 mmHg). RESULTS: A total of 176 eyes in cohort 1 and 32 in cohort 2 were analyzed. In cohort 1, IOP decreased by 3.1 mmHg at month 24 from a baseline of 18.0 (- 12.5%; p < 0.001), and medications decreased by 0.5 from 1.5 (p < 0.001); medication-free eyes rose from 22.9% to 46.4% (p < 0.001). IOP changes in the low, moderate, and high baseline tiers were + 0.9 (+ 7.8%), - 3.0 (- 16.3%), and - 9.2 (- 36.1%) mmHg; medication changes were - 0.8, - 0.6, and + 0.1. In cohort 2, IOP decreased by 6.4 mmHg from 20.0 (- 27.1%; p < 0.001), and medications decreased by 1.2 from 2.8 (p = 0.004); medication-free eyes rose from 4.3% to 30.4% (p = 0.031). Secondary IOP-lowering procedures were performed in 5.1% of cohort 1 eyes and 28.1% of cohort 2 eyes. Kaplan-Meier freedom from reoperation was 98.9% and 84.4%. No eye developed clinically significant hypotony or choroidal effusion, and there were no allograft-related vision-threatening adverse events. CONCLUSIONS: Allograft-reinforced cyclodialysis effectively lowered IOP and medication use through 24 months. TRIAL REGISTRATION: ClinicalTrials.gov NCT05506423.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Scleral Allograft-Reinforced Cyclodialysis Combined with Phacoemulsification or Performed as a Standalone Procedure: 24-Month Outcomes from the Multicenter CREST Study — Science Skim