A Prospective Evaluation of the 2-Year Efficacy and Safety of INTERCIL: A Novel Uveal Spacer for Open-Angle Glaucoma.
Lilit Voskanyan, Vahan Papoyan, Hayk Babayan, Hovsep Miroyan, Christophe Baudouin
S.V. Malayan Ophthalmological Center, Yerevan, Armenia. lilit.voskanyan@yahoo.com. · S.V. Malayan Ophthalmological Center, Yerevan, Armenia.
Key points
From the paper's conclusion- INTERCIL® provided sustained IOP and medication reduction by potentially harnessing uveoscleral outflow, without surgical risks associated with bleb- or cleft- dependent procedures, suggesting a potential new concept for patients with open-angle glaucoma requiring durable disease control.
Abstract
INTRODUCTION: Intraocular pressure (IOP) reduction is the most commonly therapeutically modifiable risk factor in glaucoma. Minimally invasive glaucoma surgeries are generally considered safe but ineffective, constrained by physiological pressure. Invasive bleb-forming filtration surgeries are effective, but associated with high risk and high rates of failure. Technologies utilizing uveoscleral rely on creation of a cyclodialysis cleft. This study evaluated a novel supraciliary uveal spacer (INTERCIL®) designed to enhance uveoscleral outflow, avoiding anterior and posterior chamber entry or bleb formation. METHODS: SAFARI 3, a prospective, single-center, single-arm study included adults with mild-to-moderate glaucoma (Shaffer grade 1-4), uncontrolled on 1-4 medications (baseline IOP 21-35 mmHg). Patients underwent standalone ab externo implantation of INTERCIL®. The primary endpoint was mean change in medicated IOP at 24 months. Secondary outcomes included medication reduction, success rates (IOP ≤ 18 mmHg with ≥ 20% reduction), safety, and quality of life. RESULTS: Twenty-nine patients with primary open-angle glaucoma (POAG) were analyzed (mean age 65.9 years; baseline IOP 23.4 ± 1.9 mmHg; medications 1.9 ± 0.9). At 24 months (n = 19), mean IOP decreased to 14.4 ± 3.1 mmHg (39% reduction); medication use decreased to 0.4 ± 0.8 (83% reduction), with 73.7% medication-free. Complete and qualified success rates were 74% and 95%, respectively. All patients achieved ≥ 20% IOP reduction by 12 and 24 months; 94.7% had IOP between 6 and 18 mmHg at 24 months. Adverse events were mild to moderate in severity. One event of inadvertent anterior chamber entry with migration affected one patient. Six cases of cataract, not deemed device- or procedure-related, were reported; causality cannot be excluded, but cataract development is not uncommon after glaucoma surgery. Device position remained stable overall, and visual function parameters showed no clinically significant changes. CONCLUSIONS: INTERCIL® provided sustained IOP and medication reduction by potentially harnessing uveoscleral outflow, without surgical risks associated with bleb- or cleft- dependent procedures, suggesting a potential new concept for patients with open-angle glaucoma requiring durable disease control. TRIAL REGISTRATION: ClinicalTrials.gov identifier, NCT05236439.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Safety of Bio-Interventional Uveoscleral Outflow Enhancement: Twelve-Month Post-Operative Results from 395 Eyes in the CREST StudymedRxiv · 2026
- Uveoscleral Outflow Enhancement as a Complementary Bio-intervention after Failed Prior Trabecular Outflow Treatment: 12-Month Outcomes of Allograft-reinforced Cyclodialysis in Open Angle GlaucomamedRxiv · 2026
- Long-Term Outcomes and Safety of Non-Cyclodialytic, Bleb-Independent Surgical Enhancement of Uveoscleral Outflow in Open-Angle Glaucoma, with Evaluation of the Role of Conjunctival Lymphatic Vessels in Suprachoroidal Drainage.Vision (Basel, Switzerland) · 2026
- PreserFlo MicroShunt Outcomes in Asia: Two-Year Results with Exploratory Comparisons of Standalone and Combined Surgery from a Regional Tertiary Centre.Journal of clinical medicine · 2026
- Safety and efficacy of micropulse transscleral laser therapy for glaucoma: a two-year follow-up.International journal of ophthalmology · 2026
- Two-year outcomes of PRESERFLO MicroShunt implantation in a real-world heterogeneous glaucoma cohort: a retrospective single-center study.Frontiers in ophthalmology · 2026