Cerebrospinal Fluid Biomarker Ratio Concordance with Amyloid Positron-Emission Tomography: A Diagnostic Test Accuracy Meta-analysis.
Pablo Martinez-Lage, Eino Solje, Julian G Martins, Martin Guess, Sraboni Sarkar
Center for Research and Memory Clinic, CITA-Alzheimer Foundation, Paseo Mikeletegi, 71, 20009, Donostia-San Sebastián, Gipuzkoa, Spain. · Institute of Clinical Medicine-Neurology, University of Eastern Finland, Yliopistonrinne 3, 70211, Kuopio, Finland.
Key points
From the paper's conclusion- pTau/Aβ42 showed the highest overall concordance with amyloid PET positivity and the lowest false positive rate versus Aβ42/Aβ40 or tTau/Aβ42.
Abstract
INTRODUCTION: Cerebrospinal fluid (CSF) biomarker ratios (amyloid-β [Aβ]42/Aβ40, phosphorylated-tau [pTau]/Aβ42, and total tau [tTau]/Aβ42) are lower-cost alternatives to amyloid positron-emission tomography (PET) for Alzheimer's disease diagnosis. Among these CSF biomarker ratios, it is not clear whether concordance with amyloid PET is highest with Aβ42/Aβ40, pTau/Aβ42, or tTau/Aβ42. To evaluate this, we conducted a diagnostic test accuracy meta-analysis. METHODS: Medline and Embase were searched for articles published between January 2008 and February 2026 reporting concordance of ≥ 1 CSF biomarker ratio with amyloid PET. Statistical analyses were performed using the bivariate model of Reitsma with the R package mada v0.5.11. RESULTS: This quantitative meta-analysis comprised 38 studies, including a total of 7504 participants, with 35 studies available for statistical analysis. All three CSF biomarker ratios (Aβ42/Aβ40, pTau/Aβ42, and tTau/Aβ42) were highly concordant with amyloid PET. However, the pTau/Aβ42 ratio showed numerically higher overall percent agreement with amyloid PET positivity (90.4%) versus Aβ42/Aβ40 (89.5%) or tTau/Aβ42 (89.2%), a significantly higher area under the curve (0.955) versus Aβ42/Aβ40 (0.921, p value for difference 0.018), and a significantly lower false positive rate (0.116) versus Aβ42/Aβ40 (0.153, p value for difference 0.015). CONCLUSION: pTau/Aβ42 showed the highest overall concordance with amyloid PET positivity and the lowest false positive rate versus Aβ42/Aβ40 or tTau/Aβ42.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Concordance between amyloid PET and CSF biomarkers in clinical setting: a cross-platform comparison and in-depth analysis of discordant casesScientific Reports · 2025
- Clinical utility of combined amyloid biomarkers in early cognitive impairment.Journal of Alzheimer's disease : JAD · 2026
- Plasma pTau 217/β-amyloid 1–42 ratio for enhanced accuracy and reduced uncertainty in detecting amyloid pathologyBrain · 2026
- Validation of plasma biomarker immunoassay-based models for predicting brain amyloid positivity in cognitively impaired individuals.Alzheimer's & dementia : the journal of the Alzheimer's Association · 2026
- Cross-Sectional and Longitudinal Diagnostic Performance of Plasma p-tau217 and p-tau217/Aβ42 in Alzheimer's Disease.Annals of neurology · 2026
- Diagnostic performance of plasma pTau217/Aβ42 ratio and a three-zone threshold model for Alzheimer’s diseaseNeurobiology of Aging · 2025