European journal of drug metabolism and pharmacokinetics

Feasibility of Predicting Human Enterohepatic Circulation of Ezetimibe Using In Vitro Culture Systems and PBPK Modeling.

Yang Liang, Fumiya Tokito, Ke Hu, Fukino Kono, Yusuke Masuo, Hiroshi Arakawa, Yukio Kato, Takeshi Katsuda,

Department of Chemical System Engineering, Graduate School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8656, Japan. · Faculty of Pharmacy, Institute of Medical, Pharmaceutical and Health Sciences, Kanazawa University, Kanazawa, Ishikawa, Japan.

Preclinical

Key points

From the paper's conclusion
  • The workflow connects assay measurements to a calibrated EHC model but does not yet establish independent bottom-up prediction or unique physiological parameters. Better constrained assay-to-model relationships and separate parent/metabolite observations are needed.

Abstract

BACKGROUND AND OBJECTIVES: Enterohepatic circulation (EHC) couples hepatic metabolism, biliary delivery, and intestinal recycling, making quantitative prediction difficult. We examined the feasibility and limitations of an in vitro-informed semi-mechanistic ezetimibe (EZE) model. METHODS: PXB hepatocyte B-CLEAR measurements informed an apparent EZE-to-glucuronide rate input, and Caco-2 measurements provided permeability context. Gallbladder timing, intestinal and systemic rates, and an observation scale were calibrated to 24 mean total ezetimibe concentration-time observations. The observation model used a normalized parent-state proxy rather than explicitly modeled circulating parent plus glucuronide. Assay time, scale-compensation, and alternative bile-release analyses evaluated the resulting assumptions. RESULTS: The reconstructed apparent clearance was ( 2.610 ± 1.714 ) × 10 - 3 mL/min/well across three independent experiments. Under the stated volume and cell-content assumptions, the rate input was 1.152 h - 1 , rounding to 1.15. The saved calibration had RMSE 5.17 ng/mL and R 2 = 0.956 , but did not reproduce all local rises. Recycled return generated secondary structure; removing return eliminated it despite a comparable overall error after scale adjustment. Time-specific hepatic inputs changed exposure substantially at fixed parameters, and adjustment of the observation scale largely compensated for these changes. CONCLUSION: The workflow connects assay measurements to a calibrated EHC model but does not yet establish independent bottom-up prediction or unique physiological parameters. Better constrained assay-to-model relationships and separate parent/metabolite observations are needed.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers