Hugo™ RAS system in the field of surgical oncology: feasibility, safety, and early oncological outcomes.
Akhil Palod, Naveena An Kumar, Nawaz Usman, Ananthakrishnan Balakrishnan, Nischitha Jayarama, Preethi S Shetty, Neethu Tomy, Vidyashankar Cj,
Department of Surgical Oncology, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India. · Department of Surgical Oncology, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India. naveenkumar.an@manipal.edu.
Key points
From the paper's conclusion- The Hugo™ RAS System is a feasible and safe platform for a wide spectrum of oncological procedures across thoracic, abdominal, and pelvic subsites. Early outcomes demonstrate acceptable perioperative morbidity and promising oncological adequacy. With appropriate training and case selection, the Hugo™ RAS system has the potential to expand the adoption of robotic surgery, particularly in resource-constrained settings.
Abstract
BACKGROUND: The Hugo™ Robotic-Assisted Surgery (RAS) System is a novel modular robotic platform with expanding applications in the field of surgical oncology. This study evaluated its feasibility, perioperative safety, and early oncological outcomes during initial adoption in a tertiary care centre. METHODS: A retrospective analysis of 75 consecutive patients who underwent robotic-assisted oncological surgery using the Hugo™ RAS System between June 2025 and May 2026 was undertaken. Demographic characteristics, operative parameters, perioperative outcomes, and early oncological results were assessed. RESULTS: Procedures were performed across thoracic (nt=13), abdominal (na=25), and pelvic (np=37) subsites. Mean console time was 298 minutes, and mean estimated blood loss was 192 ml. The overall conversion rate was 6.7% (5/75), including one conversion to thoracoscopic surgery and four conversions to open utility incision with none attributable to robotic system malfunction. The overall complication rate was 10.6%, with major complications occurring in 1.3% of patients. Mean length of hospital stay was 5 days. The 30-day and 90 day readmission rate was 4%. No perioperative or 30-day mortality was observed. While 90-day mortality was 1.3% (1/75). R0 resection was achieved in all patients. Lymph node yields were oncologically adequate across thoracic, abdominal, and pelvic subsites, with mean yields of 18.8 nodes following esophagectomy, 33 nodes for gastric resections, 20.5 nodes for colectomies, and 17.5 nodes for rectal resections, consistent with accepted oncological standards. CONCLUSIONS: The Hugo™ RAS System is a feasible and safe platform for a wide spectrum of oncological procedures across thoracic, abdominal, and pelvic subsites. Early outcomes demonstrate acceptable perioperative morbidity and promising oncological adequacy. With appropriate training and case selection, the Hugo™ RAS system has the potential to expand the adoption of robotic surgery, particularly in resource-constrained settings.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A systematic literature review of colorectal robotic surgery with the Hugo robotic-assisted surgery (RAS) system: feasibility, safety, and clinical applications.Annals of coloproctology · 2026
- Robot-assisted surgery for colorectal cancer using the Hugo™ RAS system: an observational study with the initial 118 cases and a literature review.Surgery today · 2026
- Robotic Left Minor Liver Resection With the Hugo™ RAS System: Initial ExperienceSurgical Innovation · 2026
- Upper Urinary Tract Surgery with HugoTM RAS: A Systematic Review.Journal of endourology · 2026
- The challenge of robotic surgery in oncology: a feasibility study with the Senhance™ Surgical SystemJournal of Robotic Surgery · 2025
- Retroperitoneal Renal Surgery with the Hugo™ RAS System: Feasibility, Setting and Perioperative Outcomes of the First Dedicated Series.Journal of clinical medicine · 2026