Diabetes therapy : research, treatment and education of diabetes and related disorders

Real-World Effectiveness and Safety of Pre-mix 70/30 Insulin Initiation in Poorly Controlled Type 2 Diabetes: a Multicentre Pakistani Cohort.

Azizul Hasan Aamir, Saeed Ahmed Mahar, Faisal Masood Qureshi, Ibrar Ahmad, Syed Abbas Raza, Hafiz Farhan Rashid, Mazhar Faiz Alam, Riasat Ali Khan,

Department of Diabetes, Endocrinology and Metabolic Diseases, Peshawar General Hospital, Peshawar, Pakistan. profahaamir@gmail.com. · National Institute of Cardiovascular Diseases, Karachi, Pakistan.

Observational

Key points

From the paper's conclusion
  • In routine practice, human pre-mix 70/30 insulin produced clinically meaningful and sustained HbA1c reductions with a favourable safety profile, supporting its effectiveness for insulin initiation in poorly controlled type 2 diabetes. Affordability, however, was governed by the total cost of care rather than insulin price alone.

Abstract

INTRODUCTION: In lower- and middle-income countries, insulin choice at initiation is driven as much by cost as by clinical need. Low-cost human pre-mix 70/30 insulin predominates in Pakistan, yet prospective real-world evidence on its outcomes and true cost is scarce. METHODS: In this investigator-initiated, single-arm, prospective observational study at 12 sites in Pakistan, insulin-naïve adults with type 2 diabetes and HbA1c 9% or higher despite two or more oral drugs were started on human pre-mix 70/30 insulin at physician discretion and followed for 6 months, with assessments at baseline, day 90 and day 180. The primary outcomes were change in HbA1c and incidence of hypoglycaemia (classified by American Diabetes Association levels). A descriptive cost-consequence analysis (patient out-of-pocket perspective) was a pre-specified secondary exploratory objective. RESULTS: A total of 384 of 430 screened patients were enrolled, with a mean baseline HbA1c of 11.2 ± 1.5%. HbA1c fell to 9.3 ± 1.5% at day 90 and to 8.8 ± 1.5% at day 180, a mean reduction of 2.3 ± 1.8% (p < 0.001), with no significant change in body weight. By day 180, 242 of 310 patients (78.1%) had achieved at least a 1% reduction in HbA1c, and 28 patients (9.0%) reached below 7%. Confirmed hypoglycaemia below 70 mg/dL occurred in eight patients (2.1%), and no severe or treatment-limiting events were recorded. Mean 6-month direct medical cost was 36,269 Pakistani Rupee (PKR) per patient. Insulin acquisition accounted for just PKR 7200 of this (19.8%), while consultations, injection consumables, diagnostics and self-monitoring made up the remainder. CONCLUSIONS: In routine practice, human pre-mix 70/30 insulin produced clinically meaningful and sustained HbA1c reductions with a favourable safety profile, supporting its effectiveness for insulin initiation in poorly controlled type 2 diabetes. Affordability, however, was governed by the total cost of care rather than insulin price alone.