Genes & genomics

Measured confound-related feature comparisons and design-matched evaluation in 13 public disease cohorts.

Jihye Park, Kyudong Han, Keunsoo Kang

Department of Biomedical Sciences, College of Bio-Convergence, Dankook University, Cheonan, Republic of Korea. · Department of Microbiology, College of Bio-Convergence, Dankook University, Cheonan, Republic of Korea. kyudong.han@gmail.com.

Key points

From the paper's conclusion
  • A high AUC alone does not establish that a model captures disease-specific molecular signals. Evaluating and interpreting molecular classifiers requires consideration of covariates, exposure-related molecular signatures, and dependence among samples from the same individual.

Abstract

BACKGROUND: Biomarker discovery studies using large-scale profiling data, such as transcriptomic and DNA methylation data, often report high area under the receiver operating characteristic curve (AUC) values. However, covariates, exposure-related molecular signatures, and inappropriate resampling procedures may affect the interpretation of these values. OBJECTIVE: To determine how cohort-specific factors influence the evaluation of molecular classifiers. METHODS: We reanalyzed 13 publicly available cohorts from the Gene Expression Omnibus (GEO) using the same L2-regularized logistic regression approach, with evaluation procedures matched to each cohort's study design. RESULTS: In the schizophrenia whole-blood methylation cohorts GSE84727 and GSE80417, models using smoking-associated cytosine-phosphate-guanine (CpG) sites, estimated leukocyte composition, age, and sex achieved AUCs of 0.769 and 0.860, respectively. These values were close to the AUCs of 0.809 and 0.876 obtained using the 30,000 CpG sites with the highest variance. In independent rheumatoid arthritis and inflammatory bowel disease cohorts, the smoking-associated CpG panel discriminated disease status with AUCs of 0.75 and 0.63, respectively. In psychiatric cohorts with samples from multiple brain regions per subject, keeping each subject's samples in the same cross-validation fold yielded AUCs 0.18-0.43 lower than those from sample-level evaluation. This suggests that sample-level evaluation may overestimate performance in new subjects. By contrast, neurological positive controls retained their discriminatory performance after covariate adjustment. CONCLUSION: A high AUC alone does not establish that a model captures disease-specific molecular signals. Evaluating and interpreting molecular classifiers requires consideration of covariates, exposure-related molecular signatures, and dependence among samples from the same individual.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers