Quantitative comparison of SPECT- and PET- based methods for treatment planning and dosimetry in Y-90 radioembolisation therapy.
Andrew Chacon, Aurora Poon, Wesley Ng, Sylvia J Gong, Andrew M Scott, Graeme J O'Keefe
Department of Molecular Imaging and Therapy, Austin Health, Heidelberg, Australia. · Department of Molecular Imaging and Therapy, Austin Health, Heidelberg, Australia. graeme.okeefe@austin.org.au.
Key points
From the paper's conclusion- This study compared large energy acceptance window Y-90 SPECT and PET for estimating implanted activity relative to the standard SIRTEX vial calibration method and evaluated their equivalence dosimetry.
Abstract
Quantitative post-therapy imaging is essential for verifying administered activity and assessing dose distribution following Y-90 radioembolisation. This study compared large energy acceptance window Y-90 SPECT and PET for estimating implanted activity relative to the standard SIRTEX vial calibration method and evaluated their equivalence dosimetry. The retrospective Y-90 SPECT were acquired using protocols optimised for qualitative rather than quantitative imaging. The predictive accuracy of Tc-99m MAA SPECT and compartmental models for pre-therapy dosimetry estimation was also investigated. A cohort of 28 patients treated with Y-90 resin microspheres underwent pre-therapy Tc-99m MAA SPECT and post-therapy Y-90 SPECT and PET. The regional doses (tumour, perfused liver, and lungs) were calculated using the local deposition model. Equivalence between methods was assessed using the two one-sided tests. The Y-90 SPECT and PET measurements of implanted activity was on average -3 % ± 12 % and -5 % ± 13 %, of the SIRTEX calculated method. Tumoural doses derived from Y-90 SPECT and PET were statistically equal and equivalent (mean difference -1 %, SD ± 14 %), and perfused liver doses were equivalent within ±5 Gy (mean difference 2 Gy, SD 13 Gy). Despite statistical equivalence, a 14-42% variability in individual measurements remained. Tc-99m MAA SPECT-predicted tumour doses showed closer agreement with PET doses than the partition model (4% vs 6%), while perfused liver and lung predictions were comparable. Although PET remains the current clinical reference standard, Y-90 SPECT provides clinically acceptable equivalence where PET is not available while supporting post-therapy verification and retrospective dosimetric analyses.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Quantitative Comparison of Yettirium-90 (Y90) PET/CT and Y90 SPECT/CT Voxel-Based Dosimetry post Resin Y90 Microsphere Radioembolization.Cardiovascular and interventional radiology · 2026
- Predictive value of [99mTc]Tc-MAA SPECT/CT personalised dosimetry in 90Y radioembolization of hepatocellular carcinoma: a DOSISPHERE-01 ancillary study.European journal of nuclear medicine and molecular imaging · 2026
- Technetium-99m macroaggregated albumin scan before yttrium-90 radioembolization: what to look for and why it matters.Nuclear medicine communications · 2026
- Dosimetry for Radioembolization of Liver Metastases: essential knowledge for Interventional Radiologists.The British journal of radiology · 2026
- Yttrium-90 Radioembolization for Hepatocellular Carcinoma: Clinical Evidence, Evolving Indications, and Research-Frontier Mapping.Journal of gastrointestinal cancer · 2026
- Patient-specific modeling enables specific activity optimization to maximize tumor absorbed dose in transarterial radioembolization.EJNMMI physics · 2026