Biventricular Assist Devices Versus Total Artificial Heart as Bridge-to-Transplantation Strategies: A Systematic Review and Meta-analysis.
Obay J I Ahmed, Moaz J I Ahmed, Moustafa Mahmoud Aboutabl, Mariam Mohammed, Mohamed Elserougi, Khaled Ashraf Mohamed, Tamer Ghazy, Diyar Saeed,
Faculty of Medicine, Near East University, Nicosia, Cyprus. · Faculty of Medicine, Near East University, Nicosia, Cyprus. moaz.j.i.ahmed@gmail.com.
Key points
From the paper's conclusion- TAH may be associated with higher rates of survival to transplantation after excluding potentially overlapping cohorts, while BiVAD support may be associated with higher rates of bleeding and stroke. However, all included studies were retrospective, and the certainty of evidence was low for most outcomes. These findings should therefore be interpreted with caution and require confirmation in prospective multicenter studies.
Abstract
PURPOSE: Biventricular assist devices (BiVADs) and total artificial heart (TAH) are the principal bridge-to-transplantation strategies for patients with advanced biventricular heart failure awaiting heart transplantation, but their comparative effectiveness and safety remain uncertain. This systematic review and meta-analysis compared pretransplant outcomes between the two approaches. METHODS: A systematic review and meta-analysis was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. PubMed, Scopus, Web of Science, and Cochrane Library were searched from inception through January 2026 for studies comparing BiVADs and TAH as bridge-to-transplantation strategies. Study quality was assessed using the Newcastle-Ottawa Scale, and certainty of evidence was evaluated using the GRADE framework. Random-effects models were used to compare survival to transplantation, mortality during support, support-related complications, and duration of support. RESULTS: Ten retrospective studies involving 2,242 patients met the inclusion criteria. The overall analysis showed no significant difference in survival to transplantation between patients supported with BiVADs and TAH (RR = 0.97, 95% CI (0.84, 1.13), P = 0.74). However, after excluding potentially overlapping cohorts, sensitivity analysis showed a higher rate of survival to transplantation in those supported with TAH (RR = 0.88, 95% CI (0.80, 0.97), P = 0.01). No significant difference was observed in mortality during support in the overall analysis (RR = 1.19, 95% CI (0.88, 1.61), P = 0.26) or after excluding potentially overlapping cohorts (RR = 0.98, 95% CI (0.79, 1.21), P = 0.84). BiVADs were associated with higher rates of bleeding and stroke (RR = 2.79, 95% CI (1.70, 4.59), P < 0.0001 and RR = 2.31, 95% CI (1.53, 3.50), P < 0.0001, respectively), whereas infection did not differ significantly between the two groups (RR = 1.18, 95% CI (0.50, 2.78), P = 0.70). Sensitivity analysis for stroke after excluding potentially overlapping cohorts showed a similarly higher rate in patients supported with BiVADs (RR = 2.39, 95% CI (1.46, 3.93), P = 0.0006). Duration of support did not differ significantly between both groups in the overall analysis (MD = 2.25 days, 95% CI (- 16.46, 20.96), P = 0.81) or after excluding potentially overlapping cohorts (MD = - 0.90 days, 95% CI (- 24.26, 22.46), P = 0.94). CONCLUSION: TAH may be associated with higher rates of survival to transplantation after excluding potentially overlapping cohorts, while BiVAD support may be associated with higher rates of bleeding and stroke. However, all included studies were retrospective, and the certainty of evidence was low for most outcomes. These findings should therefore be interpreted with caution and require confirmation in prospective multicenter studies.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Primary graft dysfunction after LVAD bridge-to-transplant: a systematic review and meta-analysisEuropean Heart Journal · 2026
- Continuous-Flow Left Ventricular Assist Devices in Biventricular Configuration: A Systematic Review and Comparative Meta-Analysis of HeartMate 3 and HeartWare Biventricular Assist Devices.Artificial organs · 2026
- Ventricular Assist Devices Effectively Bridge Pediatric Patients to Heart Retransplantation: An ACTION Registry Study.ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2026
- Auto-regulated bioprosthetic total artificial heart as bridge to transplantation: the EFICAS study.European heart journal · 2026
- Bridge to transplant in the contemporary allocation era: a systematic review and meta-analysis of impella versus intra-aortic balloon pumpEuropean Heart Journal · 2026
- Temporary Mechanical Circulatory Support with Axillary IABP or Impella 5.5 Versus Durable LVAD as Bridge to Heart Transplantation: A Strategy-Level Analysis in the Contemporary Allocation Era.Journal of cardiovascular development and disease · 2026