Long-Term Retrospective Evaluation of Radiochemical Yield Reproducibility of ⁶⁸Ga-Radiopharmaceuticals Using an SiO₂-Based ⁶⁸Ge/⁶⁸Ga Generator.
Raviteja Nanabala, Maroor Raghavan Ambikalmajan Pillai, Buvaneswari Gopal
Molecular Cyclotrons Private Limited, Puthuvype, Ernakulam, Kerala 682508 India. · Department of Chemistry, School of Advanced Sciences, Vellore Institute of Technology University, Vellore, Tamilnadu 632014 India.
Key points
From the paper's conclusion- The radiochemical yields are influenced as the generator ages, however, the extent of influence will depend on the chelating agent and buffer systems used for making the targeting molecule.
Abstract
BACKGROUND: The radiosynthesis of gallium-68 radiopharmaceuticals is influenced by the bifunctional chelating agents (BFCAs) used for chelation. The reaction parameters such as reagent concentration, pH, temperature and reaction time need to be carefully optimized for each targeting molecule to get the highest radiochemical yields. The parent radionuclide 68Ge used for the preparation of the generator has half-life of 271 days and hence the 68Ge/68Ga generator is often used up to a year by which time the 68Ge activity is ~ 40% of the load. However, the influence of generator aging on radiochemical yields have not been systematically reported, particularly with respect to different chelating agents in acetate buffer system. RESULTS: The clinical doses of [68Ga]Ga-HBEDCC-PSMA-11, [68Ga]Ga-DOTA-TATE, and [68Ga]Ga-DOTA-Exendin-4 were prepared using an SiO2 organic matrix-based generator supplied by Isotope Technologies Garching (ITG) in a semi-automated module with a fluidic system. Three generators were used during the course of the study and the radiochemical yields were monitored till the end of the generator life. Fluctuations in radiochemical yields were observed as the generator aged in the radiosynthesis of [68Ga]Ga-DOTA-TATE and [68Ga]Ga-DOTA-Exendin-4 whereas it was unaffected with [68Ga]Ga-HBEDCC-PSMA-11. CONCLUSIONS: The radiochemical yields are influenced as the generator ages, however, the extent of influence will depend on the chelating agent and buffer systems used for making the targeting molecule.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparative Evaluation of Buffering Systems for Optimizing the Labeling Efficiency of 68 Ga-labeled RadiopharmaceuticalsKorean Journal of Clinical Laboratory Science · 2026
- Gallium-68 and zirconium-89 complexes of DFO-analogs for molecular imaging applications using PET/CT.EJNMMI radiopharmacy and chemistry · 2026
- Chelator Conjugation Chemistry Matters: Squaramide Linker Enhances Tumor Contrast in⁶⁸ Ga-labeled Anti-CEA Nanobody TracerACS Omega · 2026
- Evaluation of the In Vivo PET Generator 140Nd/140Pr Using a HER2-Targeting Agent.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2026
- An Aliquoting Strategy for Commercial Gallium-68 Radiopharmaceutical Cold Kits.Journal of visualized experiments : JoVE · 2026
- Unnatural Amino Acid Substitutions to Improve In Vivo GRPR-Targeting Capability of [68Ga]Ga-SP01011 for Cancer Imaging.Molecular pharmaceutics · 2026