Canadian journal of anaesthesia = Journal canadien d'anesthesie

Anesthetic considerations for obstetric patients with an implanted spinal cord stimulator.

Duncan Bowes, Syva Imayan Subramaniam, Jill A Osborn, Vishal P Varshney, Anthony Chau

Department of Anesthesia, Dalhousie University, Halifax, NS, Canada. · Department of Anesthesiology, Pharmacology & Therapeutics, The University of British Columbia, Vancouver, BC, Canada.

Key points

From the paper's conclusion
  • Neuraxial anesthesia is feasible and generally safe for obstetric patients with an SCS but requires careful planning and awareness of unique risks. Antenatal anesthesiology and neuromodulation consultation, imaging review, ultrasound guidance, and patient counselling can help optimize outcomes and minimize complications.

Abstract

PURPOSE: Implantable spinal cord stimulators (SCSs) for the treatment of refractory neuropathic pain are becoming increasingly common in patients presenting for surgery, and their presence has important implications for anesthetic care. This is particularly relevant in obstetric anesthesia, where neuraxial techniques are routinely employed for labour analgesia and anesthesia for Cesarean delivery. In this Continuing Professional Development module, we synthesize the available case experience from the literature and provide practical recommendations to guide anesthesiologists in the perioperative management of obstetric patients with an SCS. PRINCIPAL FINDINGS: Numerous case reports describe the safe use of both epidural and spinal anesthetic techniques in obstetric patients with an SCS. All obstetric patients with an SCS should undergo antenatal consultation with an anesthesiologist and neuromodulation specialist (usually a pain medicine physician or neurosurgeon) responsible for managing the device. Preprocedural planning, including review of relevant imaging and a focused physical examination, is essential to minimize the risk of device damage. Ultrasound can be used to assist the provider in identifying a safe neuraxial access point and may also help to improve first-pass success. The literature suggests that prior implantation of SCS components within the epidural space may be associated with a higher risk of SCS lead movement, potential for infection, and inadequate epidural labour analgesia and surgical anesthesia. In contrast, the success of spinal anesthesia for Cesarean delivery appears largely unaffected by the presence of neurostimulation leads. In patients undergoing Cesarean delivery, management considerations include temporary device inactivation, minimizing the use of monopolar cautery, and being familiar with the course of the device's leads from the impulse generator to the stimulating electrode to avoid inadvertent surgical damage. CONCLUSIONS: Neuraxial anesthesia is feasible and generally safe for obstetric patients with an SCS but requires careful planning and awareness of unique risks. Antenatal anesthesiology and neuromodulation consultation, imaging review, ultrasound guidance, and patient counselling can help optimize outcomes and minimize complications.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers