Canadian journal of anaesthesia = Journal canadien d'anesthesie

Evaluation of deep learning for the modified Cormack-Lehane classification in videolaryngoscopic images: a prospective observational study.

Gizem Demir Senoglu, Ezgi Kara Timucin, Ozlem Ersoy Karka, Yavuz Demiraran, Gulbin Sezen

Department of Anesthesiology and Reanimation, Faculty of Medicine, Düzce University, Düzce, Türkiye. gizemsenoglu@duzce.edu.tr. · Department of Computer Engineering, Faculty of Engineering, Düzce University, Düzce, Türkiye.

Observational · n=151

Key points

From the paper's conclusion
  • The YOLOv8-based model showed promising performance in classifying modified CL grades, particularly for clinically relevant difficult views (CL grades 2b-3). Nevertheless, wide CIs and limited external validation indicate uncertainty. The model may be considered an auxiliary tool rather than an independent decision system and requires further validation in larger, multicentre data sets.

Abstract

PURPOSE: Predicting difficult intubation is still challenging, even with videolaryngoscopy. Videolaryngoscopy (VL) shows the larynx during intubation. The modified Cormack-Lehane (CL) classification grades laryngeal visibility but can vary between observers. Deep learning uses neural networks for objective, real-time airway image evaluation. We aimed to evaluate a YOLOv8-based model for object detection to automate modified CL grade classification from VL images in patients undergoing elective surgery. METHODS: In this prospective observational study, we developed a deep learning model using 346 VL images from 151 patients undergoing elective surgery. Two anesthesiologists classified images according to the modified CL system, and interobserver agreement was analysed using Cohen's kappa and weighted kappa. We split the data into training (80%), validation (10%), and test (10%) sets, with imbalance corrected via Albumentations augmentation. We evaluated the model results using sensitivity, specificity, and mean average precision with a 95% confidence interval (CI) and validated the model on 60 images not included in the training set. RESULTS: Interobserver agreement ranged from moderate (Cohen's kappa = 0.59; 95% CI, 0.53 to 0.66) to good (weighted kappa = 0.79; 95% CI, 0.75 to 0.84). In the test set, the overall recall rate was 0.87, and the specificity was 0.83. In the difficult intubation grades, recall and specificity were observed to be 0.79 (95% CI, 0.52 to 0.92) and 0.93 (95% CI, 0.78 to 0.98), respectively, for CL grade 2b, and 0.60 and 1.00, respectively, for CL grade 3. In the external validation data set (n = 60), the model achieved an overall accuracy of 0.767 with a recognition rate of 0.925 for clinically relevant CL grades 2b and 3. CONCLUSIONS: The YOLOv8-based model showed promising performance in classifying modified CL grades, particularly for clinically relevant difficult views (CL grades 2b-3). Nevertheless, wide CIs and limited external validation indicate uncertainty. The model may be considered an auxiliary tool rather than an independent decision system and requires further validation in larger, multicentre data sets.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers