Impact of ambiguous breast density assessment on mammographic diagnostic performance and comparison with AI-based quantitative density measurement.
Yuna Fukuma, Tsunehisa Nomura, Naruto Taira
Department of Breast and Thyroid Surgery, Kawasaki Medical School, 577 Matsushima, Kurashiki, 701-0192, Japan. yuna.0812@med.kawasaki-m.ac.jp. · Department of Breast and Thyroid Surgery, Kawasaki Medical School, 577 Matsushima, Kurashiki, 701-0192, Japan.
Key points
From the paper's conclusion- Visual breast-density assessment was least reproducible in the ambiguous categories between Scattered fibroglandular densities and Heterogeneously dense. Quantitative AI-based PMD assessment may provide a more reproducible measure for examining the relationship between breast density and mammographic sensitivity. Analyses of all cancers and invasive cancers showed an exploratory PMD range that reduced the DB ratio without substantially compromising sensitivity and specificity. However, this finding was not reproduced in the T1-only analysis, and further validation is required before any PMD threshold can be used for dense-breast notification or decisions regarding supplemental screening.
Abstract
BACKGROUND: Dense breast (DB) on mammogram is a risk factor for breast cancer and may hinder the detection of tumor. The U.S. Food and Drug Administration (FDA) issued a final rule requiring mammography reports to include information on breast density. However, the visual assessment of breast density is subjective and may result in considerable inter-observer and intra-observer variability. The objective of this study is to evaluate discrepancies in breast density assessment and to examine the clinical utility of quantitative breast density measurement using artificial intelligence (AI). METHODS: 1,141 mammograms from breast cancer patients were analyzed. Two expert readers independently evaluated the mammographic findings in a double-blind method without referring to clinical information. The classifications of "Scattered fibroglandular densities" and "Heterogeneously dense" were further subdivided based on diagnostic uncertainty into six groups: A, Almost entirely fat (< 25% glandular); B-1, Scattered fibroglandular densities without ambiguity (25-40%); B-2, Scattered fibroglandular densities with ambiguity (41-50%); C-1, Heterogeneously dense with ambiguity (51-60%); C-2, Heterogeneously dense without ambiguity (61-75%); D, Extremely dense (> 75%). Diagnostic performance was evaluated in terms of sensitivity and specificity. Quantitative breast density was also measured using AI-based software developed by EIZO Corporation. RESULTS: Intra-observer agreement was good (κ = 0.76 for Reader I and 0.87 for Reader II). Inter-observer agreement was also good (κ = 0.86). However, complete agreement remained relatively low for the borderline categories (Group B-2: 48% and Group C-1: 42%). Sensitivity and specificity in A, B-1, B-2, and C-1 were high (sensitivity 88.4-94.6%, specificity 85.2-94.4%). However, diagnostic performance decreased in C-2 (sensitivity 83.4% and 83.9%) and D (sensitivity 76.9%,76.9%). AI-based quantitative breast density analysis demonstrated a sensitivity of 81.4% at a PMD cutoff of 62% and 76.8% at 64%, representing a 4.6-percentage-point decrease when increasing the cutoff from 62 to 64%. Raising the PMD cutoff from 50 to 62% resulted in a reduction in the DB ratio from 27.6% to 9.9%. CONCLUSIONS: Visual breast-density assessment was least reproducible in the ambiguous categories between Scattered fibroglandular densities and Heterogeneously dense. Quantitative AI-based PMD assessment may provide a more reproducible measure for examining the relationship between breast density and mammographic sensitivity. Analyses of all cancers and invasive cancers showed an exploratory PMD range that reduced the DB ratio without substantially compromising sensitivity and specificity. However, this finding was not reproduced in the T1-only analysis, and further validation is required before any PMD threshold can be used for dense-breast notification or decisions regarding supplemental screening.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Mammographic density assessment by an artificial intelligence model for breast cancer detection in BreastScreen Norway.European radiology · 2026
- Machine learning-based analysis of average glandular dose in mammography: The role of breast density.Radiography (London, England : 1995) · 2026
- Comparison of two automated PGMI-based software tools for breast positioning quality assessment in DBT screening.European radiology experimental · 2026
- Concordance of Digital Breast Tomosynthesis (DBT) and Magnetic Resonance Imaging (MRI) Measured Tumor Size with the Pathological Gold Standard: A Retrospective Cohort Analysis by Molecular Subtype and Breast Density.Diagnostics (Basel, Switzerland) · 2026
- Missed and true interval cancers on digital breast tomosynthesis screening mammograms: radiologists' assessment and artificial intelligence markings.Acta radiologica open · 2026
- Enhancing Diagnostic Performance of Screening Mammography Readers Using an Intelligent Bayesian-Driven Adaptive Training System.Academic radiology · 2026